What Goes Wrong
- Cutout fuse bodies that track or absorb moisture fail early in service
- Terminals that do not accept both aluminium and copper conductors limit where a part can be used
- Unauthorised access to fuse assemblies in the field
- Earthing hardware that corrodes at the clamp and quietly loses its connection
- Metering hardware that has to be replaced piecemeal because the supplier changed the design
What This Buyer Needs
- Fuse bodies with mechanical and dielectric strength and non-tracking, non-hygroscopic properties
- A common body across a range of current ratings to simplify stock
- Sealing provision on assemblies installed in public places
- Earth rods and clamps for substations, stations and telecom sites
- Single phase static energy meters for residential supply
Recommended Lines
Typical Scenarios
- Low-voltage distribution and service connections
- Substation and transformer station earthing
- Telecommunication and network station earthing
- Residential metering programmes
- Overhead and pole-mounted fuse protection
From Enquiry To Delivery
Send the specification and the current ratings on your list
We confirm which stock items meet it and where a customised version is needed
Samples are supplied against the specification before volume ordering
Volume is scheduled so deliveries match the rollout rather than arriving at once
What We Supply Into This Industry
- Cutout fuses with a common body from 15 A to 100 A
- Terminals suitable for aluminium and copper conductors up to 35 sq mm
- Earth rods and earthing clamps, customisable to specification
- Single phase static energy meters
Related Reading
What A Cutout Fuse Does And How To Specify One
Cutout fuses sit at the service connection where nobody looks until something fails. The material of the body matters as much as the current rating.
Read GuideEarth Rods And Earthing Clamps The Basics
An earthing system is only as good as its worst connection, and that is usually the clamp rather than the rod.
Read GuidePower Distribution And Utilities Questions
What current range does the cutout fuse cover?
The listed cutout fuse uses a common body from 15 A to 100 A, with terminals suitable for aluminium or copper conductors up to 35 sq mm and loop in and loop out cabling contacts.
Can earth rods be made to our specification?
Yes, the earth rod is listed as customisable. Send the length, diameter and coating you require.
Where are your earth rods typically used?
The listed applications are petrochemical, oil storage, power stations, transformer substations, telecommunication stations, airports and network stations.
Supplying Power Distribution And Utilities
Send your list and quantities and we will tell you what we can cover and what we cannot.