Disposable SpO2 Sensor 9 Pin for Masimo I0171 Series 0.9M
Disposable SpO2 Sensor 9 Pin for Masimo I0171 Series 0.9M is a single-patient-use SpO2 sensor with a 9 pin male connector and a 0.9M cable, built for Masimo monitors.
- Model NoTM-I0171A-S / TM-I0171A-N / TM-I0171A-W (+14 more)
- Connector9 Pin Male
- Cable Length0.9M or Customized
- SpO2 TechnologyMasimo
- ColourWhite
- Monitor BrandsCAS Med, Datex, Draeger and GE +14 more
- Warranty3 months
- CertificationISO 13485 quality system, CE, FDA compliance
- CustomisationOEM and ODM available
Samples, datasheets and certificate copies are sent on request. Tell us the monitor model you are fitting.
Product Overview
It is documented as compatible with monitors from CAS Med, Datex, Draeger, GE, GE and Critikon and 12 further manufacturers, with the exact monitor models listed in the compatibility table below. The series carries 17 part numbers in adult, pediatric, infant and neonatal sizes. The sensor uses Masimo SpO2 technology, which is the technology the listed monitors expect. Standard housing colour is white. Warranty is 3 months.
These are SpO2 Sensors 9 Pin compatible for Masimo 1863, Mindray, Philips, GE.
Problems It Solves
A reusable sensor moves between patients, and in ICU, theatre and isolation that movement is an infection control problem that reprocessing time does not fully solve. A disposable sensor is used for one patient for a limited period, typically 24 to 72 hours, and then discarded.
For this item specifically: the part exists so a Masimo monitor already in service can keep being used when its original probe is damaged or discontinued.
Who It Is For
This part suits departments monitoring adult, pediatric, infant and neonatal patients, anyone running Masimo monitors and distributors holding stock against a mixed monitor fleet.
- Intensive care with 24-48 hour site rotation
- Operating rooms and post-anaesthesia care
- Neonatal and pediatric intensive care
- Emergency admissions with unknown history
- Sleep studies and home respiratory monitoring
Specifications
Every figure below is taken from the product documentation for this item. Where a value is not published we mark it TBC rather than estimating it.
| Name | SpO2 Sensor |
|---|---|
| Instrument Connector | 9 Pin Male |
| Length | 0.9M or Customized |
| Color | White |
| SpO2 Tech | Masimo |
| Latex-Free | Yes |
| Sterile | No |
| Warranty | 3 months |
Model Numbers in This Series
Every variant below is a separate part number within the same series. Quote the code that matches the patient size and probe style you need.
| Model No | Description |
|---|---|
TM-I0171A-S | - |
TM-I0171A-N | - |
TM-I0171A-W | - |
TM-I0171A-T | Pediatric(15-40KG) |
TM-I0171P-S | - |
TM-I0171P-N | - |
TM-I0171P-W | - |
TM-I0171P-T | Infant(3-15KG) |
TM-I0171I-S | - |
TM-I0171I-N | - |
TM-I0171I-W | - |
TM-I0171I-T | Neonate(<3KG) or Adult (>40KG) |
TM-I0171N-S | - |
TM-I0171N-N | - |
TM-I0171N-W | - |
TM-I0171N-T | - |
TM-I0171N-BF | - |
Monitor Compatibility
This part is built for the monitors listed below, taken from our product documentation. A matching plug shape alone does not guarantee a matching signal, so confirm your exact model here before ordering.
| CAS Med | 740 |
|---|---|
| Datex | Ohmeda Giraffe Infant Warmer, S/5 |
| Draeger | Infinity Delta, Infinity Delta XL, Infinity Kappa, Infinity M540, Narkomed 6400 |
| GE | Healthcare > Corometrics 128, 250, 250cx, 259, TRAM 450SL |
| GE | Healthcare |
| Critikon | Dinamap B105M, B105P, B125M, B125P, B155M, Carescape B650, Carescape B850, Carescape V100, Carescape V100 with |
| Masimo | technology, Carescape VC150, Dinamap ProCare with |
| Masimo | Pro 1000, Pro 300V2, Pro 400 V2, ProCare 300, ProCare Ausculatory 400, ProSeries V2, V300 |
| GE | Healthcare > Marquette 8000 e Eagle 1000, Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Series, Eagle, PDM Module, Procare B40, SOLAR, Smk SMV, Solar 7000, Solar 8000, Solar 8000M, Solar Series, TRAM Modular, Tram 451, i/9500, i/9500 (Tram 451N5/851N5), x50SL Series |
| Invivo | Escort II OPT30 Prism, T8 |
| Masimo | 9216, 9226, All, Pronto-7, R7CDS-1, Rad-5, Rad-57, Rad-8, Rad-87, Radical-7 |
| Mennen | Horizon XVu |
| Datascope | Accutor V, Accutorr 3, Accutorr 7, Accutorr Plus, Accutorr V, BeneView T1, BeneView T5, BeneView T8, BeneVision N1, BeneVision N12, BeneVision N15, BeneVision N17, BeneVision N19, BeneVision N22, BeneVision TD60, BeneVision TMS60, BeneVision TMS80, Beneheart D6, DPM3, DPM4, DPM5, DPM6, DPM7, Duo, EPM4, MEC 12, MPM, PM 6000, PM 6800, PM 7000, PM 8000, PM 9000, Passport 12, Passport 12m, Passport 17m, Passport 2, Passport 2LT, Passport 8, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, V12, V21, VS 8, VS 800, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, cPM 12, cPM 8, ePM 10M, ePM 12M, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC Series, iPM-9800 Natus Connex Penlon InterMed ALL |
| Philips | Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3001A, M3001A A03, M3001A A03C06, M3001A A03C12, M3001A A03C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, MP 30, SureSigns VS2, SureSigns VS3, VM4 |
| Respironics | Alice 5, Alice 6 Stryker |
| Medtronic | Physio Control Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E |
| Welch Allyn | 1500, 45NE0-E1 LX, 53S00, 53S0P, 53ST0, 53STP, 64H Series, 64M Series, 65H Series, 65M Series, 67M Series, 68M Series, 73ME-B, 73MT-B, 74ME-B, 74MT-B, 74MX-B, 75 MT-B Connex Spot, 75ME-B, 75MX-B, Propaq CS, Propaq LT, Series 420 monitors, Spot Vital Signs 42MOB, Spot Vital Signs 42MTB-E1, Spot Vital Signs lXi, Vital Signs 4700 Series |
| Zoll | E Series, M Series, R Series, X Series |
Quality Control
This part is produced under our ISO 13485 quality management system with compliance to CE Mark and FDA regulations. It passes three inspection stages: IQC on the incoming connectors, wires, cables and terminals; IPQC through cutting, stripping, crimping, injection and assembly; and OQC on packing, labels, marks, appearance, dimensions and electrical performance before it is released.
Customisation Options
Cable length on this item is stated as 0.9M or Customized, so a non-standard length can be quoted. Under our OEM and ODM service the product features, branding, packaging and labelling are customised, and we handle the regulatory documentation for your target market.
Comparison With the Alternatives
Against a reusable sensor this removes the reprocessing step and the cross-contamination path, at a higher cost per patient. Where infection control leads the decision, that trade is usually worth making.
Use Guide
- Confirm the monitor manufacturer and model against the compatibility table above.
- Check the connector on the monitor matches 9 Pin Male.
- Choose the patient size and probe style from the model table, then quote that part number.
- Apply the sensor to a clean, well-perfused site and keep the emitter and detector aligned opposite each other.
- Rotate the measurement site regularly on long recordings to protect skin integrity.
- Between patients, clean and disinfect reusable items under your own protocol; discard single-patient-use items.
What This Range Gives You
Infection control by design
One patient, one sensor. No cross-contamination path between beds and no reprocessing step for nursing staff.
Four patient sizes in every series
Adult above 30KG, pediatric 15-40KG, infant 3-15KG and neonate below 3KG, each with its own part number.
Backing material chosen for the skin in front of you
Stretch adhesive, white foam, nonwoven and transpore options for fragile neonatal skin through to active adult patients.
Consistent optics on every application
Emitter, photodetector and adhesive are new each time, so performance does not degrade with repeated cleaning.
Questions About This Product
Which monitors does Disposable SpO2 Sensor 9 Pin for Masimo I0171 Series 0.9M fit
It is documented for monitors from CAS Med, Datex, Draeger, GE, GE, Critikon, Masimo and Masimo. The compatibility table on this page lists the exact model names. If your model is not there, send it to us with a photo of the monitor socket.
What connector does it use
The instrument connector is 9 Pin Male, on a 0.9M or Customized cable.
Which part number should I quote
The series has 17 part numbers. Pick the one matching the patient size and probe style you need from the model table above, and quote that code.
What warranty applies
3 months, as stated in the specification table for this item.
How long can one disposable sensor stay on a patient
Our published guidance is that disposable sensors are used for one patient for a limited time, typically 24 to 72 hours, then discarded. ICU practice commonly rotates the site every 24 to 48 hours to protect skin integrity.
Which patient size do I order
Sizes follow patient weight: adult above 30KG, pediatric 15-40KG, infant 3-15KG, neonate below 3KG. The model table on each product page gives the part number for each size and backing material.
Can this be supplied under our own brand
Yes. OEM and ODM covers product features, branding, packaging and labelling, with the regulatory documentation handled for your market.
Quote Disposable SpO2 Sensor 9 Pin for Masimo I0171 Series 0.9M
Tell us the quantity and the monitor model you are fitting and we will confirm the part number and price.