SpO2 Adapter Cable 5 Pin for Biolight N0105 2.4M
SpO2 Adapter Cable 5 Pin for Biolight N0105 2.4M is an SpO2 extension adapter cable with a 5 pin male connector and a 2.4M cable, built for Biolight monitors.
- Model NoTM-N0105GM-L
- Connector5 Pin Male
- Cable Length2.4M or Customized
- SpO2 TechnologyDigital
- ColourGray or Blue
- Monitor BrandsContec, Biocare and Biolight
- Warranty12 months
- CertificationISO 13485 quality system, CE, FDA compliance
- CustomisationOEM and ODM available
Samples, datasheets and certificate copies are sent on request. Tell us the monitor model you are fitting.
Product Overview
It is documented as compatible with monitors from Contec, Biocare and Biolight, with the exact monitor models listed in the compatibility table below. It is supplied under part number TM-N0105GM-L. The sensor uses Digital SpO2 technology, which is the technology the listed monitors expect. Standard housing colour is gray or blue. Warranty is 12 months.
This is SpO2 adapter cable 5 Pin compatible for Biolight.
Problems It Solves
The probe on the patient and the socket on the monitor are rarely made by the same company. An adapter cable makes equipment interchangeable so a ward can keep a single probe stock across a mixed monitor fleet, instead of buying one probe type per monitor brand.
For this item specifically: the part exists so a Biolight monitor already in service can keep being used when its original probe is damaged or discontinued.
Who It Is For
This part suits anyone running Biolight monitors and distributors holding stock against a mixed monitor fleet.
- Mixed monitor fleets across departments
- Bridging a legacy monitor to current probe stock
- Biomedical engineering spares inventory
- Replacing a damaged monitor-side cable without touching the probe
Specifications
Every figure below is taken from the product documentation for this item. Where a value is not published we mark it TBC rather than estimating it.
| Name | SpO2 Adapter |
|---|---|
| Instrument Connector | 5 Pin Male |
| Length | 2.4M or Customized |
| Color | Gray or Blue |
| SpO2 Tech | Digital |
| Latex-Free | Yes |
| Sterile | No |
| Warranty | 12 months |
Model Numbers in This Series
Every variant below is a separate part number within the same series. Quote the code that matches the patient size and probe style you need.
| Model No | Description |
|---|---|
TM-N0105GM-L | SpO2 Adapter Cable 5 Pin Male to DB9 Female |
Monitor Compatibility
This part is built for the monitors listed below, taken from our product documentation. A matching plug shape alone does not guarantee a matching signal, so confirm your exact model here before ordering.
| Contec | CMS 6000, CMS 6500, CMS 6800, CMS 7000, CMS 8000, CMS 9000, CMS5000, CMS5000C, CMS5100, CMS60, CMS60C, CMS60CW, CMS60D, CMS60DW, ECG1200G, PM50, PM60D |
|---|---|
| Biocare | BM-9000,BM-9000S,FM801,FM801V |
| Biolight | M12, M6, M66, M69, M8000, M8000A, M8500, M9000, M9000A, MTD-352A Hillmed Monitors with Digital Technology Medica D Vitacare Promed PM7000 Risingmed CMS60C, RPM 9000C Sinohero S80 Sonolife SmartWave 12 Sunnex M8000A, M9000, Q5 Venni VI-1060P, VI-1220P, VI-60D |
Quality Control
This part is produced under our ISO 13485 quality management system with compliance to CE Mark and FDA regulations. It passes three inspection stages: IQC on the incoming connectors, wires, cables and terminals; IPQC through cutting, stripping, crimping, injection and assembly; and OQC on packing, labels, marks, appearance, dimensions and electrical performance before it is released.
Customisation Options
Cable length on this item is stated as 2.4M or Customized, so a non-standard length can be quoted. Under our OEM and ODM service the product features, branding, packaging and labelling are customised, and we handle the regulatory documentation for your target market.
Comparison With the Alternatives
An adapter lets one probe stock serve several monitor brands. The alternative is buying a dedicated one piece sensor per monitor type, which raises both stock value and the number of line items purchasing has to manage.
Use Guide
- Confirm the monitor manufacturer and model against the compatibility table above.
- Check the connector on the monitor matches 5 Pin Male.
- Choose the patient size and probe style from the model table, then quote that part number.
- Apply the sensor to a clean, well-perfused site and keep the emitter and detector aligned opposite each other.
- Rotate the measurement site regularly on long recordings to protect skin integrity.
- Between patients, clean and disinfect reusable items under your own protocol; discard single-patient-use items.
What This Range Gives You
One probe stock across a mixed fleet
Standardise on one probe family and let the adapter handle the monitor side.
Shielded construction for stable transmission
Shielded wire keeps SpO2 and pulse rate data clean in electrically noisy rooms with infusion pumps and diathermy nearby.
Reusable medical grade housing
Wear-resistant and anti-bending, cleaned and disinfected between uses.
Named monitor compatibility not guesswork
Every adapter page lists the manufacturer and monitor models it is built for, plus the exact connector, for example 9 Pin Male to DB9 Female.
Questions About This Product
Which monitors does SpO2 Adapter Cable 5 Pin for Biolight N0105 2.4M fit
It is documented for monitors from Contec, Biocare and Biolight. The compatibility table on this page lists the exact model names. If your model is not there, send it to us with a photo of the monitor socket.
What connector does it use
The instrument connector is 5 Pin Male, on a 2.4M or Customized cable.
What is the part number
TM-N0105GM-L - SpO2 Adapter Cable 5 Pin Male to DB9 Female.
What warranty applies
12 months, as stated in the specification table for this item.
Will any adapter with the right plug shape work
No. A matching plug shape does not guarantee a matching signal - the electrical assignment and communication between probe and monitor must match as well. Always confirm the specific monitor model against the compatibility table.
How do I identify which adapter I need
Give us the monitor manufacturer, the monitor model, and the pin count of the socket. Those three facts identify the adapter.
Can this be supplied under our own brand
Yes. OEM and ODM covers product features, branding, packaging and labelling, with the regulatory documentation handled for your market.
Quote SpO2 Adapter Cable 5 Pin for Biolight N0105 2.4M
Tell us the quantity and the monitor model you are fitting and we will confirm the part number and price.