SPS-331 AC & DC Power Source
Unique Features Technical Specification Order Info Unique Features High stability, low waveform distortion; 8 inch color touch screen, interface friendly, easy to operate; Equipped with RS232, Ethernet, and WiFi interface, SPS-331 can either support.
- Model
- SPS-331
- Product line
- Meter Test and Calibration
- Manufacturer
- Kongter Test & Measurement Co., Limited, Shenzhen, China
- Quality standard
- ISO 9001:2015
- Customisation
- Tailored configurations available on request
Send your application details straight to us on WhatsApp, WeChat or by email. We do not use enquiry forms.
Specification
Full Details for SPS-331
- High stability, low waveform distortion;
- 8 inch color touch screen, interface friendly, easy to operate;
- Equipped with RS232, Ethernet, and WiFi interface, SPS-331 can either support stand-alone operation, PC control or handy wireless terminal control;
- Communicate with tested meter thru RS485;
- Customize and develop the automatically adjustment and calibration system;
- Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit;
- Automatically detect, diagnose and alarm for failure.
- Remotely updating online, easily achieve software updating;
- Supports calibration at users’ side.
AC voltage output
AC large voltage output
Range: (Phase A) 30V, 100V, 300V, 660V, 1000V
(Phase B, C) 30V, 100V, 300V, 660V
Adjustment range: (0~120) %RG, RG refers to range, similarly hereafter; Phase A 1000V: (0~100) %RG
Adjustment resolution: 0.01%RG, 0.1%RG, 1%RG, 10%RG for option
Stability: 0.005%/1min (0.05 class), 0.01%/1min (class 0.1)
Distortion: ≤0.1% (Non-capacitive load)
Output maximum load: 25VA each phase (resistive load)
Accuracy: 0.05%RG (0.05 class), 0.1%RG (class 0.1)
AC small voltage output
Range: phase A: 75mV, 300mV, 750mV, 3V, 7.5V
Adjustment range: (0~120) %RG, RG refers to range, similarly hereafter
Adjustment resolution: 0.01%RG, 0.1%RG, 1%RG, 10%RG for option
Stability: 0.005%/1min (0.05 class), 0.01%/1min (class 0.1)
Distortion: ≤0.1% (Non-capacitive load)
Output maximum load: ≥ 25mA
Accuracy: 0.1%RG (class 0.1)
AC current output
Range: phase A: 500uA, 2mA, 10mA, 50mA, 0.2A, 0.5A, 2A, 5A, 10A, 30A\
Phase B, C: 0.2A, 0.5A, 2A, 5A, 10A, 30A
Adjustment range: (0~120) %RG, RG refers to range, similarly hereafter
Adjustment resolution: 0.01%RG, 0.1%RG, 1%RG, 10%RG for option
Stability: 0.005%/1min (0.05 class), 0.01%/1min (class 0.1)
Distortion: ≤0.1% (Non-capacitive load)
Output maximum load: 25VA each phase (resistive load)
Measurement accuracy: 200mA and above ranges: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
50mA and below ranges: 0.1%RG (Class 0.1)
Power output
Power output stability: 0.01%/2min (class 0.5), 0.02%/2min (class 0.1)
Active, reactive power measurement accuracy: 0.05%RG (class 0.5), 0.1%RG (class 0.1)
Phase angle output
Output adjustment range: 0°~360°
Output adjustment resolution: 10°, 1°, 0.1°, or 0.01°
Resolution: 0.01°
Accuracy: 0.05°
Power factor output
Adjustment range: -1 ~ 0 ~ +1
Measurement resolution: 0.0001
Accuracy: 0.0005
Frequency output
Adjustment range: 40Hz ~70Hz
Output adjustment resolution: 1Hz, 0.1Hz, 0.01Hz, 0.001Hz for option
Resolution: 0.001Hz
Accuracy: 0.001 Hz
Harmonic setup
Harmonic order: 2nd ~63rd
Harmonic amplitude: 0~40%
Harmonic angle: 0°~359.99°
Harmonic setup error: 2nd ~31st: ≤±0.1%; 32nd ~63rd≤±0.2%
DC voltage output
Range (4 lines): 100mV, 300 mV, 1V, 5V, 20V, 100V, 300V, 1000V
Adjustment range: (0~120) %RG; 1000V: (0~110) %RG
Adjustment resolution: 0.01%RG, 0.1%RG, 1%RG, 10%RG
Stability: 0.005%/1min (class 0.05), 0.01%/1min (class 0.1)
Ripple amplitude: ≤1%RG (Non-capacitive load)
Output load: 20V and above ranges: ≥10mA; 5V and below ranges: ≥25mA
Accuracy: 0.05%RG (class 0.05), 0.1%RG (class 0.1)
DC current output
Range: 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1A, 5A, 10A, 15A, 25A
Adjustment range: (0~120) %RG
Adjustment resolution: 0.01%RG, 0.1%RG, 1%RG, 10%RG
Stability: 0.005%/1min (0.05 class), 0.01%/1min (class 0.1)
Ripple amplitude: ≤1%RG
Output load: 25A: 25VA,other ranges ≥ 2V; 300mA and below ranges ≥25V
Accuracy: 10mA and above ranges: 0.05%RG (class 0.05), 0.1%RG (class 0.1)
1mA, 3mA range: 0.1%RG
Energy error measurement
Active energy basic error limit:
±0.05%RD (voltage 15V~660V, current 0.05A~36A,PF≥0.5)
±0.1%RD (voltage 15V~660V, current 0.02A~0.05A,PF=1)
Reactive energy basic error limit:
±0.1%RD (voltage 15V~660V, current 0.05A~36A,PF≥0.5)
±0.2%RD (voltage 15V~660V, current 0.02A~0.05A,PF=1)
General parameters
Power supply: 90~265VAC/DC
Frequency: 50Hz~60Hz
Consumption: 50VA~1000VA
Environment condition: 20℃~30℃,relative humidity≤85%
Storage environment: -20℃~50℃
Size: 600mm (L) × 440mm (W) × 176mm (H)
Weight: 28Kg
SPS-331 contains 2 models with different accuracy below:
SPS-331C, Accuracy Class: 0.05
SPS-331B, Accuracy Class: 0.1
Request A QuoteCustomers also viewed:
MTS-50 Meter Test System
SPS-50 3 Phase Power Source (50A)
MTS-100 Meter Test SystemFAQ
Questions About This Model
Is this model certified
All Kongter products are strictly accredited by the international quality standard ISO 9001:2015.
Can this be customised for my application
Yes. Customised configurations are part of the standard offering. Tell us the system voltage, capacity or load you need to cover.
What is the lead time
Lead time depends on the configuration. Message us on WhatsApp at +86 135 1009 2292 or email [email protected] with your requirement and we will confirm it.
Do you provide training and support
Yes. Kongter's R&D team develops equipment aimed at field use, and product support is part of the offering. See the support pages for what is covered.
How do I get a quotation
Message us on WhatsApp or WeChat at +86 135 1009 2292, email [email protected], or call +86-755-2691 6832.
Related Models
More From Meter Test and Calibration








Request a Quote
Ask for a Price on SPS-331
Tell us the system you need to test and the quantity. We reply with a quotation and lead time.