MTS-122 Meter Test System
Unique Features Technical Specification Order Info Unique Features Integration of high accurate reference meter and reliable power source Eligible to calibrate indicating meter, electrical transducer, energy meter, RTU and so on Accuracy: U, I, P, kWh:.
- Model
- MTS-122
- Product line
- Meter Test and Calibration
- Manufacturer
- Kongter Test & Measurement Co., Limited, Shenzhen, China
- Quality standard
- ISO 9001:2015
- Customisation
- Tailored configurations available on request
Send your application details straight to us on WhatsApp, WeChat or by email. We do not use enquiry forms.
Specification
Full Details for MTS-122
- Integration of high accurate reference meter and reliable power source
- Eligible to calibrate indicating meter, electrical transducer, energy meter, RTU and so on
- Accuracy: U, I, P, kWh: ±0.05%; Q, kvarh : ±0.1%
- U, I, P stability: 0.01%RG/3min; Distortion of AC Voltage and AC Current: ≤ 0.2%
- Measurement Scope:
AC Voltage: 300mV~1000V (Single phase), 57.7V~660V (3 phase)
AC Current: 2mA~30A (Single phase), 0.2A~30A (3 Phase)
DC Voltage: 75mV~750V; DC Current: 100μA~30A - Export 2nd-63rd harmonics, and measure & analyze the harmonics
- With relay output and pulse output, MTS-122 remotely controls tests of indication and information response time
- Modular design with 8” color TFT screen and user-friendly interface, easy to operate
- Automatic Calibration System can be customized according to customer’s requirements
- Exchange the testing settings and testing records thru USB
- Remotely updating online, easily achieve software updating
- With connectors of RS-232, RS-485, I/O, Ethernet, USB and WiFi, convenient for PC operation, firmware update and remote diagnosis.
- Self-protection, alarm and display overload location for output overload, Voltage short-circuit, Current open-circuit
- Self-diagnosis for amplifier failure and internal module communication failure
- Test energy meters with the accuracy of Class 0.2 and below (Class 0.05 equipment)
AC large Voltage output:
Range: (L1) 30V, 100V, 300V, 660V, 1000V;
(L2 &L3) 30V, 100V, 300V, 660V;
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter; L1 1000V: (0~100) %RG;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 30V and upper gears; 20VA each phase;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
AC small Voltage output:
Range: L1: 75mV, 300mV, 750mV, 3V, 7.5V;
Adjusting range: (0~120) %RG, RG refers to range;
Adjusting range: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.02%/2min;
Distortion: ≤0.2% (Non capacitive load);
Max output load: ≥25mA;
Measurement accuracy: 0.1%RG;
AC Current output:
Range: (L1) 2mA, 2mA,10mA, 50mA, 200mA, 500mA, 2A, 5A, 10A, 30A;
(L2 & L3) 200mA, 500mA, 2A, 5A, 10A, 30A;
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 20VA (30A gear); 50mA and below gear: ≥15V;
Measurement accuracy: 200mA and above gears: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1);
50mA and below gears: 0.1%RG (Class 0.1);
Power output
Power output stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Active/reactive power measurement accuracy: 0.05%RG;
Phase output
Output adjusting range: 0°~360°;
Output adjusting degree: 10°, 1°, 0.1°, 0.01° for option;
Resolution: 0.01°;
Measurement accuracy: 0.05°.
Power factor output:
Adjusting range: -1 ~ 0 ~ +1;
Measuring resolution: 0.0001;
Measurement accuracy: 0.0005
Frequency output
Adjusting range: 40Hz ~70Hz;
Output adjusting degree: 1Hz, 0.1Hz, 0.01Hz, 0.001Hz for option;
Resolution: 0.001Hz;
Accuracy: 0.002 Hz.
Harmonic setting
Harmonic times: 2nd ~63rd;
Harmonic content: 0~40%
Harmonic phase: 0°~359.99°
Harmonic set error: 2nd ~31st times: ≤±0.1%,32nd ~63rd times: ≤±0.2%;
DC Voltage output
Range: 100mV, 300 mV, 1V, 5V, 20V, 100V, 300V, 1000V;
Adjusting range: (0~120) %RG; 1000V: (0~100) %RG
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Output load: ≥50mA;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
Ripple content: no more than 1%.
DC Current output
Range: 100μA, 300μA, 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1A, 5A, 10A, 25A, 30A;
Adjusting range: (0~120) %RG;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Output load: 25A: 25VA; 5~10A: 2V; 1A and lower gear ≥30V;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
Ripple content: no more than 1%.
DC input Voltage measurement
Range: ±10V;
Measuring range: (0-150) %RG;
Basic error limit: 0.02%RG
Ripple measuring error: (5%RD + 0.1%), RD refer to ripple measured value;
Resolution: 0.001%RG.
DC input Current measurement
Range: ±20mA;
Measuring range: (0-150) %RG;
Basic error limit: ±0.02%RG
Ripple measuring error: ± (5%RD + 0.1%), RD refer to ripple measured value;
Resolution: 0.001%RG.
Energy error measurement:
Active energy basic error limit:
0.05%RD (Voltage 15V~660V, Current 0.05A~36A, PF≥0.5);
0.1%RD (Voltage 15V~660V, Current 0.02A~0.05A, PF=1);
Reactive energy basic error limit:
0.1%RD (Voltage 15V~660V, Current 0.05A~36A, PF≥0.5);
0.2%RD (Voltage 15V~660V, Current 0.02A~0.05A, PF=1);
Other parameters:
Power supply: 90-265VAC/DC
Power frequency: 50Hz~60Hz
Power consumption: 50VA~1000VA
Working environment: 20℃~30℃,Humidity: RH≤85%
Storage environment: -20℃~50℃
Size: 600(L)× 440 (W)× 176(H)mm
Weight: 30kg
MTS-122 contains 2 models with different accuracy below:
MTS-122C, Accuracy Class: 0.05
MTS-122B , Accuracy Class: 0.1
Customers also viewed:
SPS-50 3 phase power source (50A)
SRM-362 Standard Reference Meter
MTS-100 Meter Test SystemsFAQ
Questions About This Model
Is this model certified
All Kongter products are strictly accredited by the international quality standard ISO 9001:2015.
Can this be customised for my application
Yes. Customised configurations are part of the standard offering. Tell us the system voltage, capacity or load you need to cover.
What is the lead time
Lead time depends on the configuration. Message us on WhatsApp at +86 135 1009 2292 or email [email protected] with your requirement and we will confirm it.
Do you provide training and support
Yes. Kongter's R&D team develops equipment aimed at field use, and product support is part of the offering. See the support pages for what is covered.
How do I get a quotation
Message us on WhatsApp or WeChat at +86 135 1009 2292, email [email protected], or call +86-755-2691 6832.
Related Models
More From Meter Test and Calibration








Request a Quote
Ask for a Price on MTS-122
Tell us the system you need to test and the quantity. We reply with a quotation and lead time.