Preformed Line Fittings
Preformed Dead End Clamp, NL
Peformed dead end clamp is intended for a single (one-time) use.Heliformed tension clamp intended for use by trained craftspeople only.

Overview
Preformed Dead End Clamp, NL Description
Heliformed Dead End Clamp
NL
1.Preformed dead end clamp is intended for a single (one-time) use and for the specified application. 2.Heliformed tension clamp intended for use by trained craftspeople only. dead end clamp should not be used by anyone who is not familiar with and trained in the use of it. 3.When working in the area of energized lines with this product,extra care should be taken to prevent accidental electrical contact. 4.For proper performance and personal safety be sure to select the proper size with preformed Armor Rods and clamps according the conductors size before application. 5.Tension clamp are precision devices.To insure proper performance,they should be stored in cartons under cover and handled carefully. 6.The dead end clamp are simple installation,except the need the screwdriver to seperated the conductor ends,usually needn’t a ny other tools,just install by hand.
Preformed Dead End Clamp for ACSR
Heliformed Tension Clamp for AAAC
1KV Insulated Helical Conductor Tension Clamp
10KV Insulated Helical Conductor Tension Clamp
Specifications
Codes Ranges and Dimensions
Figures below are reproduced from the CROP catalogue for this item.
| Model | Applicable type of guide wire(GB1179-83) | Reference length(mm) | Color code | Optional matching fittings | |
| Applicablediameter of guide wire(mm) | ACSR(LGJ/LGJF) | ||||
| NL-16/3 | 5.55 | 16/3 | 444 | Brown | TC-05-B |
| NL-25/4 | 6.96 | 25/4 | 546 | Yellow | |
| NL-35/6 | 8.16 | 35/6 | 622 | Red | |
| NL-50/8 | 9.6 | 50/8 | 685 | Yellow | |
| NL-70/10 | 11.4 | 70/10 | 736 | Blue | |
| NL-95/15 | 13.61 | 95/15 | 876 | Red | TC-07-B |
| NL-70/40 | 13.6 | 70/40 | 876 | ||
| NL-95/20 | 13.87 | 95/20 | 876 | ||
| NL-120/7 | 14.5 | 120/7 | 876 | ||
| NL-120/20 | 15.07 | 120/20 | 889 | Black | TC-10-B |
| NL-120/25 | 15.74 | 120/25 | 889 | ||
| NL-150/8 | 16 | 150/8 | 889 | ||
| NL-150/20 | 16.67 | 150/20 | 1016 | Green | |
| NL-150/25 | 17.1 | 150/25 | 1016 | ||
| NL-150/35 | 17.5 | 150/35 | 1016 | ||
| NL-185/10 | 18 | 185/10 | 1016 | ||
| NL-185/25 | 18.9 | 185/25 | 1155 | Orange | |
| NL-185/30 | 18.88 | 185/30 | 1155 | ||
| NL-210/10 | 19 | 210/10 | 1155 | ||
| NL-185/45 | 19.96 | 185/45 | 1155 | ||
| NL-210/25 | 19.98 | 210/25 | 1155 | ||
| NL-210/35 | 20.68 | 210/35 | 1155 | ||
| NL-240/30 | 21.6 | 240/30 | 1270 | Blue | TC-10-B |
| NL-240/40 | 21.66 | 240/40 | 1270 | ||
| NL-240/55 | 22.4 | 240/55 | 1700 | Purple | TC-12-B |
| NL-300/15 | 23.01 | 300/15 | 1442 | Blue | TC-10-B |
| NL-300/20 | 23.43 | 300/20 | 1442 | ||
| NL-300/25 | 23.76 | 300/25 | 1620 | Brown | TC-10-B |
| NL-300/40 | 23.94 | 300/40 | 1620 | ||
| NL-300/50 | 24.26 | 300/50 | 1770 | Brown | TC-12-B |
| NL-400/20 | 26.91 | 400/20 | 1860 | Red | TC-12-B |
| NL-400/25 | 26.64 | 400/25 | 1860 | ||
| NL-400/35 | 26.82 | 400/35 | 1860 |
| Model | Applicable diameter of guide wire(mm) | Applicable type of guide wire(GB1179-83)AAC(LJ) | Reference length (mm) | Color code | Optional matching fittings | |
| min. | max. | |||||
| NL-16/LJ | 4.62 | 5.16 | 16 | 406 | Blue | TC-070B |
| NL-25/LJ | 5.8 | 6.53 | 25 | 444 | Orange | |
| NL-35/LJ | 7.35 | 8.26 | 35 | 622 | Red | |
| NL-50/LJ | 8.27 | 9.25 | 50 | 685 | Green | |
| NL-70/LJ | 10.4 | 11.68 | 70 | 736 | Blue | |
| NL-95/LJ | 11.69 | 13.11 | 95 | 800 | Orange | |
| NL-120/LJ | 13.12 | 14.66 | 120 | 876 | Red | |
| NL-150/LJ | 14.67 | 16.59 | 150 | 889 | Black | |
| NL-185/LJ | 16.6 | 18.77 | 185 | 1016 | Green | |
| NL-210/LJ | 16.6 | 18.77 | 210 | 1016 | Green | |
| NL-240/LJ | 18.78 | 21.26 | 240 | 1155 | Orange | |
| NL-300/LJ | 21.27 | 24.05 | 300 | 1270 | Blue | |
| NL-400/LJ | 24.06 | 27.2 | 400 | 1422 | Brown | |
| NL-500/LJ | 27.21 | 30.78 | 500 | 1651 | Orange | TC-10-B |
| Model | Applicable diameter of guide wire(mm) | Applicable wiremodel below 1KV GB12527-90 | Applicable wiremodel below 10KV GB14049-93 thinner insulation | Reference length (mm) | Color code | Optional matching fittings | |
| min. | max. | ||||||
| NL-10/JY-1KV | 5.82 | 6.53 | 10 | 460 | Orange | TC-05-B | |
| NL-16/JY-1KV | 6.55 | 7.34 | 16 | 530 | Yellow | ||
| NL-25/JY-1KV | 8.28 | 9.25 | 25 | 690 | Green | ||
| NL-35/JY-1KV | 9.26 | 10.39 | 35 | 690 | Yellow | ||
| NL-50/JY-1KV | 10.4 | 11.68 | 50 | 740 | Blue | ||
| NL-70/JY-1KV | 11.6 | 13.11 | 70 | 25 | 790 | Orange | |
| 35 | |||||||
| NL-95/JY-1KV | 13.12 | 14.66 | 50 | 860 | Purple | ||
| NL-120/JY-1KV | 14.67 | 16.59 | 95 | 70 | 889 | Blue | TC-07-B |
| 120 | |||||||
| NL-150/JY-1KV | 16.6 | 18.77 | 150 | 95 | 980 | Red | |
| NL-185/JY-1KV | 18.78 | 21.26 | 185 | 120 | 1016 | Brown | TC-10-B |
| 150 | |||||||
| NL-240/JY-1KV | 21.27 | 24.05 | 240 | 185 | 1016 | Green | |
| NL-300JYQ-10KV | 24.06 | 27.2 | 240 | 1016 | Black | ||
| 300 |
| Model | Applicable diameter of guide wire(mm) | Applicable wiremodel below 10KV GB14049-93 ordinary insulation | Reference length(mm) | Color code | Optional matching fittings | |
| min. | max. | |||||
| NL-10/JY-10KV | 10.40 | 11.68 | 10 | 740 | Blue | TC-05-B |
| NL-16/JY-10KV | 11.69 | 13.11 | 16 | 790 | Orange | |
| NL-25/JY-10KV | 13.12 | 14.66 | 25 | 860 | Purple | |
| NL-35/JY-10KV | 14.67 | 16.59 | 35 | 889 | Blue | TC-07-B |
| NL-50/JY-10KV | 14.67 | 16.59 | 50 | 889 | Blue | |
| NL-70/JY-10KV | 16.60 | 18.77 | 70 | 980 | Red | |
| NL-95/JY-10KV | 18.78 | 21.26 | 95 | 1016 | Brown | |
| NL-120/JY-10KV | 18.78 | 21.26 | 120 | 1016 | Brown | |
| NL-150/JY-10KV | 21.27 | 24.05 | 150 | 1016 | Green | TCB-10-B |
| NL-185/JY-10KV | 24.06 | 27.20 | 185 | 1016 | Black | |
| NL-240/JY-10KV | 24.06 | 27.20 | 240 | 1016 | Black | |
| NL-300/JY-10KV | 27.21 | 30.78 | 300 | 1016 | Purple |
Product Images



Ordering and Support
From Enquiry To Delivered Order
Send The Requirement
Item code, conductor or cable size and quantity, or a drawing and a photograph for a non standard part.
Quotation
Price, packing, carton quantity and lead time are confirmed against the catalogue reference.
Sample or Tooling
Samples are sent for approval. Parts that need a new mould go through the in house mould division.
Production and Shipment
Production to IEC and GB standards, then packing and shipment on the agreed terms.
Answers
Frequently Asked Questions
How do I choose the right size?
Is Preformed Dead End Clamp, NL available as a sample before a production order?
Which standards do CROP products follow?
Can items be produced to our own drawing?
How do I obtain the PDF catalogue?