Piercing Connector
Insulated Piercing Connector for abc Cable
Insulated piercing connector for abc cable are used to tap or splice applications on an energized conductor (tap must never be under load).
- *Copper tinned teeth can be used for copper or aluminum conductor.
- Aluminum teeth can be used for aluminum conductor.
- OEM/ODM: Can be customized

Overview
Insulated Piercing Connector for Abc Cable Description
Insulated piercing connector for abc cable are used to tap or splice applications on an energized conductor (tap must never be under load).CROP insulated piercing connector is manufactured in such a way that it can connect LV ABC and network connection conductors, whether they are aluminum or copper conductors.
Product Parameter of Insulated Piercing Connector
When the clip nut is tightened, the teeth of the contact plate will pierce the insulating layer of the LV ABC and achieve good contact due to the penetration of the conductor and the large contact area. The contact plate is made of electrolytic metal sheet with excellent electrical conductivity and very high tensile strength, so it can pierce the insulating layer even at very low temperatures. Tighten until mechanical damage occurs to the cutting head nut. Additional tightening is allowed up to the maximum mechanical load, a maximum of 1.5 turns from the moment the shear head nut is damaged. It can be installed with voltage, but proper protection equipment must be used.
Insulated Piercing Connector Catalogue Download
Specifications
Codes Ranges and Dimensions
Figures below are reproduced from the CROP catalogue for this item.
| Models | PCT13C 95/10 | PCT13CB 95/10 |
|---|---|---|
| Main Line(mm2) | 6-95 | 6-95 |
| Service Line (mm2) | 1.5-10 | (B) 1.5-10 |
| Bolt No. | 1 | 1 |
| Torque (Nm) | 10NM | 10NM |
| Remarks | ISO to ISO | ISO to Bare |
| Models | PCT13C 70/35 | PCT13C 95/50 | PCT13C 120/25 | PCT13C 150/50 | PCT13C 185/35 | PCT13CB 70/35 | PCT13CB 95/50 |
|---|---|---|---|---|---|---|---|
| Main Line(mm2) | 16-70 | 16-95 | 25-120 | 50-150 | 50-185 | 16-70 | 16-95 |
| Service Line (mm2) | 4-35 | 4-50 | 6-25 | 4-50 | 6-35 | (B)4-35 | (B)4-50 |
| Bolt No. | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Torque (Nm) | 15NM | 17NM | 17NM | 17NM | 17NM | 15NM | 17NM |
| Remarks | ISO to ISO | ISO to ISO | ISO to ISO | ISO to ISO | ISO to ISO | ISO to Bare | ISO to Bare |
| Models | PCT13C 95/95 | PCT13C 150/150 | PCT13CB 95/95 | PCT13CB 150/150 |
|---|---|---|---|---|
| Main Line(mm2) | 16-95 | 16-150 | 16-95 | 16-150 |
| Service Line (mm2) | 16-95 | 16-150 | (B)16-95 | (B)16-150 |
| Bolt No. | 1 | 1 | 1 | 1 |
| Torque (Nm) | 17-23NM | 23NM | 23NM | 23NM |
| Remarks | ISO to ISO | ISO to ISO | ISO to Bare | ISO to Bare |
Product Images



Ordering and Support
From Enquiry To Delivered Order
Send The Requirement
Item code, conductor or cable size and quantity, or a drawing and a photograph for a non standard part.
Quotation
Price, packing, carton quantity and lead time are confirmed against the catalogue reference.
Sample or Tooling
Samples are sent for approval. Parts that need a new mould go through the in house mould division.
Production and Shipment
Production to IEC and GB standards, then packing and shipment on the agreed terms.
Answers
Frequently Asked Questions
How do I choose the right size?
Is Insulated Piercing Connector for abc Cable available as a sample before a production order?
Which standards do CROP products follow?
Can items be produced to our own drawing?
How do I obtain the PDF catalogue?
Next Step
Get A Price For Insulated Piercing Connector for abc Cable
Send the code, the size and the quantity. Drawings for non standard versions are welcome.