Insulation Piercing Connector
The waterproof insulation piercing connectors are suitable for majority types of LV ABC conductors as well as connections to service and lighting cable cores.When tightening the bolts, the teeth of the contact plates penetrate the insulation and establish a perfect contact. The bolts are tightened until the heads shear off. Tightening torque guaranteed (fuse nut). Stripping of insulation is avoided. Service condition: 400/600V, 50/60Hz, -10℃ to 55℃ Standard: IEC 61284, EN 50483, IRAM2435, NFC33 020.
Material
Body: Thermoplastic polyamide 66 with fiberglass Connecting bridge: Copper tinned, Brass tinned, Al Sealing parts: Flexible PVC End cap: Flexible PVC Grease: Silica gel Bolt: Hot dip galvanized steel, 8.8 grade Washer, Nut: Hot dip galvanized steel Fuse nut: Zinc alloy
Features
• Tested for watertightness at a voltage of 6 kV for 30 min in a waterbath • Potential free tightening bolts allow safe installations on life lines • Bimetallic,suitable for aluminium and copper conductors • Long neck 13 mm shear head nut ensuring reliable installations • Components not isolated, end cap attached to body • Insulation material made of weather and UV resistant glass fibre reinforced polymer
Hot Sale Insulation Piercing Connector
Insulation piercing connector PCT13C series
Piercing connector CRT series
IPC connector JBC series
10kV insulation piercing connector
Insulated fasten clamp PT series
Tap Off Connector Underground Ring Type
Insulation Piercing Connector for Street Lighting
Piercing Connector for Low Voltage Aerial Bundled Cables
10 KV Piercing Tap Connectors
10 KV Underground IPC Connector
Insulated Fasten Clamp
JBDC is to lead the branch from the bare main line while JBDD is to lead the branch from the insulated mainline,tighten the bolt with an idea torque which ensure the best quality of connection.
Material: High strength aIuminium alloy anti-UV plastic
Multi-Tap Insulation Pierciing Connector
Adaptor is used to turn multiple conductors of low voltage.Whole adaptor is inserted into the IPC with piercing teeth who penetrate through the insulation.This joint is 100% waterproof.The adaptor can be installed with any IPC who allows you to transfer the required voltage,and has the ability yo carry the required number of conductors. Standard: IEC 61284, EN 50483, IRAM2435, NFC33 020.
Material: Body in Aluminum alloy with tinned surface coating.Plastic Cover
Undergrounding Ring Type Tap Off Connector
4 core or 3 1/2 core ring type tap off connector with IP2X protection and piercing retardant system. On the connector ring is pressembled on the main conductor the plastic housing offer full protection against touching live contact teeth(finger test),test to EN 60529.During pressembly on the main conductor the contact protection system detects early contact teeth via the predetermined breaking point to ensure a large operational safety during tap off conductor assembly. Material High strength aluminum alloy (AIMgSi),corrosion resistant,Contacts in brass (Cu Zn),electro tinned,insulation parts are glassfiber reinforced PA,screw are steel,grade 8.8.
How to Install Insulation Piercing Connector
Single screw insulation piercing clamp Installation
1.Adjust the nut of the puncture line clamp to a proper position, and insert the branch line into the branch line cap cover.
2.Insert the main line. If the main line has two layers of insulation, a certain length of outer insulation should be stripped at the connection position.
3.Put the main and branch lines in the proper position and keep them parallel. First, tighten the nut by hand to fix the clamp.
4.Tighten the nuts evenly with a sleeve wrench of the corresponding size until the top breaks off and the installation is complete.
Single Screw Installation Piercing Connector Installation Diagram
Twin Screw Insulation Piercing Connector Installation
1.First unscrew the wire clamp and insert the main wire into the main wire groove. Do not twist the main wire with the knife ruler. Note whether the wire diameter range corresponds to this wire clamp.
2.Put the branch line into the branch line slot. Note the same as above.
3.Tighten with a socket wrench. Disable open-end wrenches.
4.Note that the two nuts should be screwed down synchronously in sequence.
5.When tightened to a certain strength, the constant torque nut is broken and the installation is completed.
Twin Screw Installation Piercing Connector Installation Diagram
Images












Related Products
Piercing Connector
10KV Insulation piercing connector
Piercing Connector
10KV Insulation piercing connector with grounding rings
Piercing Connector
Aerial Fuse holder FCC-V
Piercing Connector
Aluminium contact teeth piercing connector CRS-7 used for aluminium conductor
Piercing Connector
Bimetallic IPC Connector Insulation Piercing Connector
Piercing Connector
Branch Piercing Clamp
Piercing Connector
BT Connector JDBC, JDBB Series
Piercing Connector
Cable Wire Connector IPC PCT13 Series
Piercing Connector
Answers
Frequently Asked Questions
Where can I see the full Insulation Piercing Connector range?
Which standards do CROP products follow?
Can items be produced to our own drawing?
How do I obtain the PDF catalogue?
Who does CROP normally supply?
Next Step
Quotation For Insulation Piercing Connector
Send the sizes and the quantity and a price with matching codes comes back to you.