Insulation Piercing Connector Installation

Single Screw Insulation Piercing Clamp Installation

  • Adjust the nut of the puncture line clamp to a proper position, and insert the branch line into the branch line cap cover.
  • Insert the main line. If the main line has two layers of insulation, a certain length of outer insulation should be stripped at the connection position.
  • Put the main and branch lines in the proper position and keep them parallel. First, tighten the nut by hand to fix the clamp.
  • Tighten the nuts evenly with a sleeve wrench of the corresponding size until the top breaks off and the installation is complete.

Single Screw Installation Piercing Connector Installation Diagram

Twin Screw Insulation Piercing Connector Installation

  • First unscrew the wire clamp and insert the main wire into the main wire groove. Do not twist the main wire with the knife ruler. Note whether the wire diameter range corresponds to this wire clamp.
  • Put the branch line into the branch line slot. Note the same as above.
  • Tighten with a socket wrench. Disable open-end wrenches.
  • Note that the two nuts should be screwed down synchronously in sequence.
  • When tightened to a certain strength, the constant torque nut is broken and the installation is completed.

Twin Screw Installation Piercing Connector Installation Diagram

How to Install Insulation Piercing Connector

Answers

Frequently Asked Questions

Where can I see the matching products?
The Piercing Connector category page carries the full item list for this subject.
Which standards do CROP products follow?
All CROP products are made to comply with IEC and GB standards. Where a project calls for a national or utility specification, send the standard reference with your enquiry and the matching item will be quoted.
Can items be produced to our own drawing?
Yes. Non-standard and OEM orders are part of the normal range. Send the drawing, a picture, the weight or the written specification to [email protected] or by WhatsApp and a quotation will be prepared against your requirement. CROP also runs its own mould division for plastic, SMC and stamped parts.
How do I obtain the PDF catalogue?
The catalogue is issued on request. Ask for the section you need by email or WhatsApp on 0086 138 6832 9796 and the PDF will be sent back to you. The catalogue page lists every section that is available.

Next Step

Ask A Technical Question

Send the question with your cable or conductor data and an engineer will answer it.

Chat on WhatsApp