⚠ Information Notice: Profile content was collected from https://kongter.com/ and may be inaccurate, outdated, or incomplete. Weisourcing makes no guarantee of accuracy. Please contact the supplier directly to verify all product specs, pricing, and capabilities before transacting.
← weisourcing.com / suppliers / Top 262 · Songpingshan, Shenzhen 518057

Kongter

kongter.com · Songpingshan, Shenzhen 518057

Visit official site →
Top 262 Long-Term Client · Songpingshan, Shenzhen 518057

Songpingshan Shenzhen — high-tech professional test + measurement equipment for preventative maintenance + power solutions. Battery management + DC ground fault location + AC load bank + oil moisture sensors. ISO 9001:2015. BT-302/BT-3915 battery testers + BDL-3926C data logger + K-3837 ground fault locator + K-3986 charger discharger + K-1000 AC load bank. Industries: telecom + power utility + locomotive + offshore platform + data centers.

Kongter Test & Measurement Co., Limited (kongter.com) — high-tech company dedicated to professional test and measurement equipment for preventative maintenance and power solutions. Main business: battery management + DC ground fault location + AC load bank + oil moisture sensors. Leading solution provider for these products in China. Products include battery condition analyzer + battery/DC load ba

Songpingshan Shenzhen
Tech district
ISO 9001:2015
Quality standard
4 main domains
Battery+DC ground+AC load+oil moisture
8+ products
BT-302 to K-1000
5+ industries
Telecom+utility+locomotive+offshore+data centers

About Kongter.

Kongter Test & Measurement Co., Limited (kongter.com) — high-tech company dedicated to professional test and measurement equipment for preventative maintenance and power solutions. Main business: battery management + DC ground fault location + AC load bank + oil moisture sensors. Leading solution provider for these products in China. Products include battery condition analyzer + battery/DC load bank + DC ground fault locator + meter test system + whole line of AC load bank. Specific products: BT-302 battery tester (for inter-cell connection testing per IEEE recommendations 10% intercell connections quarterly + all annually); BT-3915 (cell resistance/conductance/voltage; battery 5-6000Ah; resistance 0.00-100mΩ; voltage 0-16VDC; for utility + telecom + data center UPS + motive power); BDL-3926C Battery Data Logger (12V-480V, 1.2/2/6/12V battery types); K-3837 Ground Fault Locator (DC ground fault + insulation pinpoint, DIN VDE compliance); K-3986 Charger Discharger Complex; K-1000 Series AC Load Bank (resistive + resistive/reactive, rack to container, sectionalized control, real-time display, PC software open com protocol). All products ISO 9001:2015 accredited. R&D commitment to field-proven advanced solutions. Industries: telecom + power utility + locomotive + offshore platform + data centers + UPS. Address: #405, Bldg 62, Songpingshan, Langshan Rd., Shenzhen 518057. Tel: +86-755-2691-6832. Email: [email protected]. WhatsApp/WeChat: +86 135 1009 2292.

Applications: Telecom infrastructure operators (battery backup) · power utility companies (substation + grid) · locomotive (rail) battery systems · offshore platform standby power · data centers + UPS systems · DC system insulation monitoring · transformer + insulating oil moisture monitoring · electrical meter calibration laboratories · global test + measurement + battery management + DC ground fault + AC load bank export.

BrandKongter
CompanyKongter Test & Measurement Co., Limited (Songpingshan, Shenzhen)
LocationSongpingshan, Shenzhen 518057
Address#405, Bldg 62, Songpingshan, Langshan Rd., Shenzhen 518057, China
Phone+86-755-2691-6832 · WhatsApp/WeChat +86 135 1009 2292

14 products from Kongter.

Real product names, models, and specs as listed on https://kongter.com/. Image hotlinks point back to the supplier's own site.

01

BT-302 Battery Tester (Inter-Cell)

BT-302
BT-302 · battery tester · inter-cell resistance · IEEE quarterly + annual

BT-302 Battery Tester — designed for inter-cell connection testing. Solves battery failures from loose inter-cell connections. Per IEEE: 10% intercell connections tested quarterly + all annually. Precise test of internal resistance/conductance and inter-cell resistance.

02

BT-3915 Battery Tester

BT-3915
BT-3915 · resistance + conductance · 5-6000Ah · 0-100mΩ · 0-16VDC

BT-3915 Battery Tester / Resistance Conductance Tester. Cell resistance + conductance + voltage. Battery 5-6000Ah. Resistance 0.00-100mΩ. Voltage 0-16VDC. For utility + telecom + data center UPS + motive power.

03

BDL-3926C Battery Data Logger

BDL-3926C
BDL-3926C · battery monitoring · 12V-480V · 1.2/2/6/12V types

BDL-3926C Battery Data Logger / Monitoring System — small modular design, easy install/operate. Tests 1.2V/2V/6V/12V battery types. 12V-480V customizable for different battery systems. Easy expansion for all UPS systems.

04

K-3837 Ground Fault Locator

K-3837
K-3837 · DC ground fault locator · DIN VDE compliance

K-3837 Ground Fault Locator / Detector — DC ground fault location and elimination. Bad insulation/grounding is big hazard, costly to repair upon power break-off. DIN VDE compliant.

05

K-3986 Charger Discharger Complex

K-3986
K-3986 · charger + discharger + DC power supply · battery string

K-3986 Charger Discharger Complex / DC Power Supply — multi-function complex for battery testing + charging + discharging + DC power supply.

06

K-1000 Series AC Load Bank

K-1000
K-1000 · AC load bank · resistive + resistive/reactive · rack to container

K-1000 Series AC Load Bank — whole range of AC load bank including resistive only and resistive/reactive combined. Small rack mounted to huge container types. For full load test of generator set, UPS, AC power systems. Sectionalized control + real-time display.

07

Battery Condition Analyzer

Battery condition analyzer
Battery condition analyzer · preventative maintenance

Battery Condition Analyzer — preventative maintenance battery condition analysis equipment.

08

Battery / DC Load Bank

DC load bank
DC load bank · battery testing · load

Battery / DC Load Bank — DC load bank for battery system testing applications.

09

Insulation Online Monitoring System

Insulation monitor
Insulation online monitoring · DC system · continuous

Insulation Online Monitoring System — continuous online monitoring of DC system insulation.

10

AC Signal Interruption Detection

AC signal detect
AC signal interruption detection · power system monitoring

AC Signal Interruption Detection Instrument — for power system monitoring.

11

DC Ripple Signal Detector

DC ripple
DC ripple signal detector · DC power quality

DC Ripple Signal Detector — DC ripple signal detection for DC system power quality monitoring.

12

High Accuracy Current Sensor

Current sensor
High accuracy current sensor · power system

High Accuracy Current Sensor — high accuracy current sensors for power system applications.

13

Meter Test System

Meter test
Meter test system · electrical meter testing

Meter Test System — system for testing electrical meters.

14

Oil Moisture Sensor

Oil moisture
Oil moisture sensor · transformer + insulating oil

Oil Moisture Sensor — moisture sensors for transformer and insulating oil monitoring.

What sets Kongter apart.

Songpingshan Shenzhen tech district

Located in Songpingshan, Shenzhen 518057 — Shenzhen tech district base.

ISO 9001:2015 accreditation

All products strictly accredited by ISO 9001:2015 international quality standards.

Four main business domains

Four main business domains: battery management + DC ground fault location + AC load bank + oil moisture sensors.

Leading China solution provider

Now the leading solution provider for these products in China — domestic market leadership.

Comprehensive product portfolio (14+ instruments)

Comprehensive portfolio: BT-302/BT-3915 + BDL-3926C + K-3837 + K-3986 + K-1000 + condition analyzer + DC load bank + insulation monitor + AC signal detector + DC ripple detector + meter test + oil moisture + current sensor.

R&D field-proven advanced solutions

R&D team committed to field-proven, easy-to-use, more effective solutions.

Cost-smart + reliable + flexible field operation

Products cost smart with reliable performance and selection for field operation.

IEEE-aligned testing methodology

BT-302 aligned with IEEE 10% intercell connections quarterly + all annually recommendations.

DIN VDE compliance for ground fault

K-3837 ground fault locator aligned with DIN VDE requirements.

Five+ industry application breadth

Five+ industry applications: telecom + power utility + locomotive + offshore platform + data centers + UPS.

PC software open communication protocol

K-1000 AC load bank PC software com protocol open for IT system integration.

Direct line to Kongter.

Phone+86-755-2691-6832 · WhatsApp/WeChat +86 135 1009 2292
Address#405, Bldg 62, Songpingshan, Langshan Rd., Shenzhen 518057, China