RCT Plastic Ring Current Transformer
Made by Qianwei Current Transformer Co., Ltd. in Liushi, Wenzhou. Tell us the ratio, accuracy class and burden and we will confirm the exact frame, the price and the lead time.
- Category
- Current Transformers
- Series
- RCT Plastic Ring CT
- Manufacturer
- Qianwei, Wenzhou China
- Certification
- ISO 9001 and CE
Technical data
AC circuit as the current energy measurement or relay protection, products using molded case insulation, smal
l size, weight light, using the mounting plate fixed installation
RCT Current transformer:
|
Primary current: Secondary current: Standard approval: Maximum voltage: Frequency: Rated load: Class: Short-time thermal current: Rated security coefficient: |
30A-300A 5A,1A VDE0414,BS7626,IEC60044-1 0.72/3KV 50-60Hz 1.5VA,2.5VA,5VA,7.5VA 0.5,1.0 Ith=60×Ih FS<5 |
| Model | Primary/secondary |
| RCT-25 | 15/5A 20/5 30/5 40/5 50/5 60/5 75/5 100/5A |
| RCT-35 | 30/5 50/5 60/5 80/5 100/5 120/5 150/5 200/5 250/ 300/5A |
| RCT-60 | 300/5 400/5 500/5 600/5 800/5 1000/5 1200/5A |
| RCT-90 | 1000/5 1200/5 1500/5 1600/5 2000/5A |
| RCT-110 | 2000/5 2500/5 3000/5 4000/5 5000/5A |
|
Model |
Primary / Secondary |
Busbar Hole Dimensions(mm) |
Rated Burden (VA) |
Accuracy Class |
Rated Voltage |
|
RCT-35 |
30/5A~300/5A |
φ=35mm |
1.5~10 |
0.5 / 1.0 |
0.72KV(AC) |
|
RCT-58 |
300/5A~1200/5A |
φ=58mm |
2.5~15 |
0.5 / 1.0 |
0.72KV(AC) |
|
RCT-90 |
800/5A~1600/5A |
φ=90mm |
5~15 |
0.5 / 1.0 |
0.72KV(AC) |
|
RCT-110 |
1000/5A~3000/5A |
φ=110mm |
10~20 |
0.5 / 1.0 |
0.72KV(AC) |
|
RCT-130 |
2000/5A~6000/5A |
φ=130mm |
20~30 |
0.5/ 1.0 |
0.72KV(AC) |
Specifical remind:
1: Working Place: Indoor
2:Ambient temperature : -5ºC ~ 40ºC
Questions about this model
How do I get a price for the RCT Plastic Ring Current Transformer
Email [email protected] or message us on WhatsApp with the model, the ratio, the accuracy class, the burden in VA and the quantity.
What is the burden and why do you ask for it
The burden is the total termination impedance seen by the transformer: the measuring instrument, the connecting leads and the winding itself. Accuracy class cannot be guaranteed without it, and long lead runs add resistance that has to be counted.
Can this model be customised
Ratios, secondary current and mounting can often be adapted within the same frame. Send us the requirement and we will confirm what the frame allows.
Ask about the RCT Plastic Ring Current Transformer
Give us the ratio, the accuracy class and the burden and you will get a firm model number and price.