Skip to content

Current transformer manufacturer in Liushi, Wenzhou since 1998

[email protected]+86-577-62700712

QIANWEICURRENT TRANSFORMER
Menu
Home All products Current TransformersMES Europe Hottest CTCA Europe Hottest CTDX Europe Low Cost CTMSQ Asian Hottest CTNSQ Asian Hottest CTDM Equal to IME MINI CTRLC Russian CTSLC Spain CTDSC Low Cost CTMBO Equal to ASK CTABO High Accuracy CTMSQ Asian Hottest CTCK Small Fixed Type CTTP Square Split Core CTFlexible Rogowski coil CTDBP Square Split Core CTSCT Clamp Split Core CTUK Ring Splict Core CTOutdoor WaterProof SplitRCT Plastic Ring CTMR Tape Wrapping CTRS Plastic Ring Type CTTAS Three Phase CTD364 Low Cost 3P CTD 3Phase MCCB CTPSDH Plastic ProtectionPR 5P20 Protection CTFOX Current TransformerASK Current TransformerASR Current TransformerKBU Current Transformer0.5-0.66KV Outdoor Resin12KV Indoor Resin CT24KV Indoor Resin CT36KV Medium CT&VTMINI current transformerZero leakage protect CTResidual fire monitor CTWorldwide CT ShowroomEuropean BrandAmerican CTAsian CTGermany CTLovato CTRayleigh CTABB CTTE CTMBS CTIME CTHobut CTEFEN CTLumel CTCurrent TransducersMeter SeiresPower SeriesStandard Single ConverterVoltage SeriesPanel MetersAnalogue Panel MeterMoving Iron AC&Volt MeterMoving Iron Switch ACMoving Coil DC MeterMoving Coil Rectifier MeterSingle Phase Power MeterFrequency MeterThree Phase Power MeterPower Factor MeterDemand AmmeterLED Synchroscope MeterHour MeterDigital Panel MeterDigital AC&Volt MeterDigital DC&Volt MeterDigital Power MeterDigital Power Factor MeterDigital Frequency MeterDigital Three-Phase MeterDC ShuntsEurope DIN43703 ShuntAmerica Based ShuntSwithchBoard ShuntKWH Meter ShuntSpecial Customized ShuntRelaysTime RelayVoltage RelayCurrent RelaySolid Stage RelayLevel Control RelayLatching RelayIntermediate RelayThemal RelayArc Fault ProtectionElectronic TestersLED electronic testerSolar EnergySolar DC SurgeOther ProductsElectric Pin BusbarBusbar InsulatorWelding TorchShielded ConnectorBell transformer Quality and Certificates Downloads Distributors About Us Contact
Moving Coil DC Meter

Moving Coil DC Meter

Moving Coil DC Meter

Made by Qianwei Current Transformer Co., Ltd. in Liushi, Wenzhou. Tell us the ratio, accuracy class and burden and we will confirm the exact frame, the price and the lead time.

Category
Panel Meters
Manufacturer
Qianwei, Wenzhou China
Certification
ISO 9001 and CE

Technical data

Product Name SD series type dc ammeter 90 degrees
Category D.C. Ammeters > SD-C96A C80A C72A C48A
Model SD-C96A SD-C72A SD-C72A

Accuracy class:SD-C96, SD-C80A and SD-C72A ,1.5.SD-C48,2.5

For through current:50uA 100uA 200uA 300uA 500uA 1mA 5mA 10mA 15A 20mA; 4-20mA 50mA 100mA 200mA 300mA 500mA 1A 2A 3A 5A 6A 10A 15A 20A 25A 30A 40A 50A 60A ;The up limit of through current for SD-C48A is 50A.

For transformation ration:5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A......10KA;The meters should be used with a shunt of which external secondary voltage 60mV or 75mV.As long as the incoming voltage keep the same,dial scales of all models in this series can be exchanged yet remain the accuracy.

Overload rate of ammeters:1.non-overload 2.1.2times 3.2times

For through voltage:50mV 60mV 75mV 100mV 200mV 300mV 500mV 1V 5V 10V 30V 50V 100V 150V 200V 300V 400V 450V 500V 600V.

For transformation ration:450V 500V 600V 1000V 1500V 2000V 3000V 5000V;the meters should be used under the circumstance of 5mA incoming rated current and with an external fixedresistor.

Overload rate of voltmeters:1.non-overload 2.1.2times

Principles of measurement and the features.Each magneto-electrical meter consists of permanent magnet steel and a moving coil with two tractive balance springs.When low current flows through the magnet coil and magnetic field appears,the pointer deflects with the movement of magnet coil.When the torque and the restoring torque keep a balance,the pointer on the moving iron will point to a scale mark,which is the measured value.

The magneto-electrical meters can be merely used for DC measurement.The advantages are high accuracy and sensitivity,low power consumption and the uniform scale,as well as insensitivity to temperature and external magnetic field,while the disadvantage is the low overload capacity.

Product Name SD series type dc ammeter 240 degrees
Category D.C. Ammeters > SD-GC96A GC72A GC48A
Model SD-GC96A

Accuracy class:SD-GC96, SD-GC72A ,1.5.SD-GC48,2.5

For through current:100uA 200uA 300uA 500uA 1mA 5mA 10mA 15A 20mA; 4-20mA 50mA 100mA 200mA 300mA 500mA 1A 2A 3A 5A 6A 10A 15A 20A 25A 30A 40A 50A ;The up limit of through current for SD-GC48A is 15A.

For transformation ration:The meters should be used with a shunt of which primary voltage is 5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A......10KA and secondary voltage is 60mV or 75mV.As long as the incoming voltage keep the same,dial scales of all models in this series can be exchanged yet remain the accuracy.

Overload rate of ammeters:1.non-overload 2.1.2times 3.2times

For through voltage:50mV 60mV 75mV 100mV 200mV 300mV 500mV 1V 5V 10V 30V 50V 100V 150V 200V 300V 400V 450V 500V 600V.

For transformation ration:Primary voltage is 450V 500V 600V 1000V 1500V 2000V 3000V 5000V;it should be used under the circumstance of 5mA incoming rated current and with an external fixedresistor.

Overload rate of ammeters:1.non-overload 2.1.2times

Principles of measurement and the features.Each 240°magneto-electrical meter consists of permanent magnet steel and a moving coil with two tractive balance springs.When low current flows through the magnet coil and magnetic field appears,the pointer deflects with the movement of magnet coil.When the torque and the restoring torque keep a balance,the pointer on the moving iron will point to a scale mark,which is the measured value.

240° magneto-electrical meters can be merely used for DC measurement.The advantages are high accuracy and sensitivity,low power consumption and the uniform scale,as well as insensitivity to temperature and external magnetic field,while the disadvantage is the low overload capacity.

Product Name SD series fangyuan type dc ammeter
Category D.C. Ammeters > SD-C80A C60A C50A
Model SD-C80A SD-C60A SD-C50A

Accuracy class:2.5

For through current:100uA 200uA 300uA 500uA 1mA 5mA 10mA 15A 20mA; 4-20mA 50mA 100mA 200mA 300mA 500mA 1A 2A 3A 5A 6A 10A 15A 20A 25A 30A 40A 50A 60A.

For transformation ration:5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A......10KA;The meters should be used with a shunt of which external secondary voltage 60mV or 75mV.

Overload rate of ammeters:1.non-overload 2.1.2times

For through voltage:50mV 60mV 75mV 100mV 200mV 300mV 500mV 1V 5V 10V 30V 50V 100V 150V 200V 300V 400V 450V 500V 600V.

For transformation ration:450V 500V 600V 1000V 1500V 2000V 3000V 5000V;the meters should be used under the circumstance of 5mA incoming rated current and with an external fixedresistor.

Overload rate of voltmeters:1.overload-free

Principles of measurement and the features:Each magneto-electrical meter consists of permanent magnet steel and a moving coil with two tractive balance springs.When low current flows through the magnet coil and magnetic field appears,the pointer deflects with the movement of magnet coil.When the torque and the restoring torque keep a balance,the pointer on the moving iron will point to a scale mark,which is the measured value.

The magneto-electrical meters can be merely used for DC measurement.The advantages are high accuracy and sensitivity ,low power consumption and the uniform scale ,as well as insensitivity to temperature and external magnetic field,while the disadvantage is the low overload capacity.

Product Name SD series of circular dc ammeter
Category D.C. Ammeters > SD-C670A
Model SD-C670A

Accuracy class:2.5

For through current:0.5A 1A 1.5A 3A 5A 10A 15A 20A 25A 30A 40A 50A 60A.

For transformation ratio:The meters should be used with a current transformer of which primary current 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A 120A 150A......10KA and external secondary current 1A or 5A.

Overload rate of ammeters:1.non-overload 2.1.2times

For through voltage:30V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V 500V 600V.

For transformation ratio:The meters should be used with a voltage transformer of which primary voltage is 400V 450V 500V 600V 1000V 1500V 2000V 3000V 5000V......450KV and external secondary voltage 100V.

Overload rate of voltmeters:1.overload-free

Principles of measurement and the features:Each electromagnetic meter consists of a magnet coil with a magnet coil with a static sheet iron inside and a moving sheet iron with a tractive balance spring .When current flows through the magnet coil,magnetic field appears.Under such circumstance,the static and the moving sheet irons are magnetized simultaneously and remain the same polarity.According to the theory that the same polarities repel each other,repulsive force between the two irons makes the pointer deflect.When the torque and the restoring torque keep a balance,the pointer on the moving iron will point to a scale mark,which is the measures value.

The electromagnetic meters can be used for AC circuits under ordinary circumstance as well as for DC circuits instructed with TRMS.The structure of the meters is simple,yet the accuracy and overload capacity are high,as well they can be used in 50/60hz circuits.Special frequency should be marked out in ordering.

Product Name SD series circular dc ammeter
Category D.C. Ammeters > SD-C62T2A C65A C52A C45A
Model SD-C62T2A SO-C52A SO-C45A

Accuracy class:2.5

For through current:100uA 200uA 300uA 500uA 1mA 5mA 10mA 15A 20mA; 4-20mA 50mA 100mA 200mA 300mA 500mA 1A 2A 3A 5A 6A 10A 15A 20A 25A 30A 40A 50A 60A.

For transformation ration:5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A......10KA;The meters should be used with a shunt of which external secondary voltage 60mV or 75mV.

Overload rate of ammeters:1.non-overload 2.1.2times

For through voltage:50mV 60mV 75mV 100mV 200mV 300mV 500mV 1V 5V 10V 30V 50V 100V 150V 200V 300V 400V 450V 500V 600V.

For transformation ration:450V 500V 600V 1000V 1500V 2000V 3000V 5000V;the meters should be used under the circumstance of 5mA incoming rated current and with an external fixedresistor.

Overload rate of voltmeters:1.overload-free

Product performance:All the meters are equipped with pure white silk-screen printing dial scale.The movement is made of aluminum alloys and permanent magnet steel so that it is vibration-resistant and heat-resistant.The case is made of PC plastics ,of which the resistant temperature can be up to 120°C.The resistant voltage is higher than 2000V.This kind of meter is easy to install with high-strengthen plastics grip piece by screwing down the nut so that the meter is of high immobility.

Principles of measurement and the features:Each magneto-electrical meter consists of permanent magnet steel and a moving coil with two tractive balance springs.When low current flows through the magnet coil and magnetic field appears,the pointer deflects with the movement of magnet coil.When the torque and the restoring torque keep a balance,the pointer on the moving iron will point to a scale mark,which is the measured value.

The magneto-electrical meters can be merely used for DC measurement.The advantages are high accuracy and sensitivity ,low power consumption and the uniform scale ,as well as insensitivity to temperature and external magnetic field,while the disadvantage is the low overload capacity.

Product Name HL series type dc ammeter
Category D.C. Ammeters > HL-C96A C72A
Model HL-C96A

Accuracy class:1.5

For through current:50uA 100uA 200uA 300uA 500uA 1mA 5mA 10mA 15A 20mA; 4-20mA 50mA 100mA 200mA 300mA 500mA 1A 2A 3A 5A 6A 10A 15A 20A 25A 30A 40A 50A 60A.

For transformation ration:5A 10A 15A 20A 25A 30A 40A 50A 60A 75A 100A......10KA;The meters should be used with a shunt of which external secondary voltage 60mV or 75mV.As long as overload rate and the in incoming current keep the same,dial scales of all models in this series can be exchanged yet remain the accuracy.

Overload rate of ammeters:1.non-overload 2.1.2times

For through voltage:50mV 60mV 75mV 100mV 200mV 300mV 500mV 1V 5V 10V 30V 50V 100V 150V 200V 300V 400V 450V 500V 600V.

For transformation ration:450V 500V 600V 1000V 1500V 2000V 3000V 5000V;the meters should be used under the circumstance of 5mA incoming rated current and with an external fixedresistor.

Overload rate of voltmeters:1.non-overload 2.1.2times

Principles of measurement and the features:Each magneto-electrical meter consists of permanent magnet steel and a moving coil with two tractive balance springs.When low current flows through the magnet coil and magnetic field appears,the pointer deflects with the movement of magnet coil.When the torque and the restoring torque keep a balance,the pointer on the moving iron will point to a scale mark,which is the measured value.

The magneto-electrical meters can be merely used for DC measurement.The advantages are high accuracy and sensitivity ,low power consumption and the uniform scale ,as well as insensitivity to temperature and external magnetic field,while the disadvantage is the low overload capacity.



(wechat)

Questions about this model

How do I get a price for the Moving Coil DC Meter

Email [email protected] or message us on WhatsApp with the model, the ratio, the accuracy class, the burden in VA and the quantity.

What is the burden and why do you ask for it

The burden is the total termination impedance seen by the transformer: the measuring instrument, the connecting leads and the winding itself. Accuracy class cannot be guaranteed without it, and long lead runs add resistance that has to be counted.

Can this model be customised

Ratios, secondary current and mounting can often be adapted within the same frame. Send us the requirement and we will confirm what the frame allows.

Ask about the Moving Coil DC Meter

Give us the ratio, the accuracy class and the burden and you will get a firm model number and price.

WhatsApp