IP65 WaterProof Split CT
Made by Qianwei Current Transformer Co., Ltd. in Liushi, Wenzhou. Tell us the ratio, accuracy class and burden and we will confirm the exact frame, the price and the lead time.
- Category
- Current Transformers
- Series
- Outdoor WaterProof Split
- Manufacturer
- Qianwei, Wenzhou China
- Certification
- ISO 9001 and CE
Technical data
PARAMETERS
| Technical parameters | |
|---|---|
| Standards | IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 |
| Accuracy Class | 0.5S, 0.5%, 1%, 3% |
| Range of primary rated current | 300-1200A |
| Range of Rated load | ≤10VA |
| Rated frequency | 50/60Hz |
| Rated secondary current | 5A or 1A |
| Secondary winding power frequency withstand voltage | 3kV, 1min |
| Safety Factor Rating | (FS) <10 |
| Flame retardant ABS plastic shell inside, jaw waterproof apron. | |
| Mechanical parameters | |
| Aperture (mm) | Φ55 |
| Dimensions (W×D×H) (mm) | 180×138×52 |
| Weight (kg) | 2 |
| Working conditions | |
| Operating temperature | -35°C to +55°C, not exceeding +40°C |
| Environment | outdoors or indoors |
| The Height of above sea level | 0- 3000m |
| Conditions | No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed. |
SELECTION GUIDE
| Model | Primary rated current | Rated load | Aperture (mm) | Description (mm) | Weight (kg) | Material | Water-proof |
|---|---|---|---|---|---|---|---|
| LMCK055-10 | 300-1200A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP65 |
| LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 |
| LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) |
| LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) |
| LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) |
| LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 2.1 | Resin | silicon case (option) |
(wechat)
click to other model catalogue:
Other models in Outdoor WaterProof Split
Questions about this model
How do I get a price for the IP65 WaterProof Split CT
Email [email protected] or message us on WhatsApp with the model, the ratio, the accuracy class, the burden in VA and the quantity.
What is the burden and why do you ask for it
The burden is the total termination impedance seen by the transformer: the measuring instrument, the connecting leads and the winding itself. Accuracy class cannot be guaranteed without it, and long lead runs add resistance that has to be counted.
Can this model be customised
Ratios, secondary current and mounting can often be adapted within the same frame. Send us the requirement and we will confirm what the frame allows.
Ask about the IP65 WaterProof Split CT
Give us the ratio, the accuracy class and the burden and you will get a firm model number and price.