Skip to content

Current transformer manufacturer in Liushi, Wenzhou since 1998

[email protected]+86-577-62700712

QIANWEICURRENT TRANSFORMER
Menu
Home All products Current TransformersMES Europe Hottest CTCA Europe Hottest CTDX Europe Low Cost CTMSQ Asian Hottest CTNSQ Asian Hottest CTDM Equal to IME MINI CTRLC Russian CTSLC Spain CTDSC Low Cost CTMBO Equal to ASK CTABO High Accuracy CTMSQ Asian Hottest CTCK Small Fixed Type CTTP Square Split Core CTFlexible Rogowski coil CTDBP Square Split Core CTSCT Clamp Split Core CTUK Ring Splict Core CTOutdoor WaterProof SplitRCT Plastic Ring CTMR Tape Wrapping CTRS Plastic Ring Type CTTAS Three Phase CTD364 Low Cost 3P CTD 3Phase MCCB CTPSDH Plastic ProtectionPR 5P20 Protection CTFOX Current TransformerASK Current TransformerASR Current TransformerKBU Current Transformer0.5-0.66KV Outdoor Resin12KV Indoor Resin CT24KV Indoor Resin CT36KV Medium CT&VTMINI current transformerZero leakage protect CTResidual fire monitor CTWorldwide CT ShowroomEuropean BrandAmerican CTAsian CTGermany CTLovato CTRayleigh CTABB CTTE CTMBS CTIME CTHobut CTEFEN CTLumel CTCurrent TransducersMeter SeiresPower SeriesStandard Single ConverterVoltage SeriesPanel MetersAnalogue Panel MeterMoving Iron AC&Volt MeterMoving Iron Switch ACMoving Coil DC MeterMoving Coil Rectifier MeterSingle Phase Power MeterFrequency MeterThree Phase Power MeterPower Factor MeterDemand AmmeterLED Synchroscope MeterHour MeterDigital Panel MeterDigital AC&Volt MeterDigital DC&Volt MeterDigital Power MeterDigital Power Factor MeterDigital Frequency MeterDigital Three-Phase MeterDC ShuntsEurope DIN43703 ShuntAmerica Based ShuntSwithchBoard ShuntKWH Meter ShuntSpecial Customized ShuntRelaysTime RelayVoltage RelayCurrent RelaySolid Stage RelayLevel Control RelayLatching RelayIntermediate RelayThemal RelayArc Fault ProtectionElectronic TestersLED electronic testerSolar EnergySolar DC SurgeOther ProductsElectric Pin BusbarBusbar InsulatorWelding TorchShielded ConnectorBell transformer Quality and Certificates Downloads Distributors About Us Contact
CA Current Transformer

CA Europe Hottest CT

CA Current Transformer

Made by Qianwei Current Transformer Co., Ltd. in Liushi, Wenzhou. Tell us the ratio, accuracy class and burden and we will confirm the exact frame, the price and the lead time.

Manufacturer
Qianwei, Wenzhou China
Certification
ISO 9001 and CE

Technical data

$1.2/per CA-MES62/30 100/5A 1cl.hottest model in Europe,South Africa,Russia Market Samples free!
NAME:CA/CP-CURRENT-TRANSFORMER


CA/CP seRIES current transformer total 10specifications is compact smaller than other models with the current ratio of the tranformer issamll,clamshell-style terminal cover is well protected by the second terminal.with related accessories, you can use DIN rail mounting,acourrent from 5A to 3000A.


CURRENT TRANSFORMERS CA/CP-62/20

Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security

30A-200A
5A,1A
VDE0414,BS7626,IEC44-1
0.72/3KV
50-60Hz
2.5VA,5VA,10VA,15VA
0.5,1.0
Ith=60×Ih
FS<5

CA Current Transformer

CURRENT TRANSFORMERS CA/CP-62/30

Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security

30A-400A
5A,1A
VDE0414,BS7626,IEC44-1
0.72/3KV
50-60Hz
2.5VA,5VA,10VA,15VA
0.5,1.0
Ith=60×Ih
FS<5

CA Current Transformer

CURRENT TRANSFORMERS CA/CP-62/40

Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security

60A-600A
5A,1A
VDE0414,BS7626,IEC44-1
0.72/3KV
50-60Hz
2.5VA,5VA,10VA,15VA
0.5,1.0
Ith=60×Ih
FS<5


CA Current Transformer

CURRENT TRANSFORMERS CA/CP-74/40

Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security

60A-600A
5A,1A
VDE0414,BS7626,IEC44-1
0.72/3KV
50-60Hz
2.5VA,5VA,10VA,15VA
0.5,1.0
Ith=60×Ih
FS<5


CA Current Transformer

CURRENT TRANSFORMERS CA/CP-74/50

Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security

200A-1000A
5A,1A
VDE0414,BS7626,IEC44-1
0.72/3KV
50-60Hz
2.5VA,5VA,10VA,15VA
0.5,1.0
Ith=60×Ih
FS<5


CA Current Transformer

CURRENT TRANSFORMERS CA/CP-86/60

Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security

400A-1500A
5A,1A
VDE0414,BS7626,IEC44-1
0.72/3KV
50-60Hz
2.5VA,5VA,10VA,15VA
0.5,1.0
Ith=60×Ih
FS<5


CA Current Transformer

CURRENT TRANSFORMERS CA/CP-104/80

Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security

600A-2000A
5A,1A
VDE0414,BS7626,IEC44-1
0.72/3KV
50-60Hz
2.5VA,5VA,10VA,15VA
0.5,1.0
Ith=60×Ih
FS<5

CA Current Transformer

CURRENT TRANSFORMERS CA/CP-140/100

Primary current:
Secondary current:
Standard approval:
Maximum voltage:
Frequency:
Rated load:
Class:
Short-time thermal current:
Rated security

800A-3000A
5A,1A
VDE0414,BS7626,IEC44-1
0.72/3KV
50-60Hz
2.5VA,5VA,10VA,15VA
0.5,1.0
Ith=60×Ih
FS<5

What is the Current transformer:
Current transformer principle is based on the principle of electromagnetic induction. Current transformer is by the closure of the core and winding composition. It's a winding turns are very few, string in the need to measure the current line, so it often have line of all current through the secondary winding turns more, cascading in measuring instrument and protection circuit, current transformer at work, it's two loop is always closed, so measuring instrument and protection circuit in series with the coil impedance is small, the working state of the current transformerCA Current Transformer


Questions about this model

How do I get a price for the CA Current Transformer

Email [email protected] or message us on WhatsApp with the model, the ratio, the accuracy class, the burden in VA and the quantity.

What is the burden and why do you ask for it

The burden is the total termination impedance seen by the transformer: the measuring instrument, the connecting leads and the winding itself. Accuracy class cannot be guaranteed without it, and long lead runs add resistance that has to be counted.

Can this model be customised

Ratios, secondary current and mounting can often be adapted within the same frame. Send us the requirement and we will confirm what the frame allows.

Ask about the CA Current Transformer

Give us the ratio, the accuracy class and the burden and you will get a firm model number and price.

WhatsApp