Skip to content

Current transformer manufacturer in Liushi, Wenzhou since 1998

[email protected]+86-577-62700712

QIANWEICURRENT TRANSFORMER
Menu
Home All products Current TransformersMES Europe Hottest CTCA Europe Hottest CTDX Europe Low Cost CTMSQ Asian Hottest CTNSQ Asian Hottest CTDM Equal to IME MINI CTRLC Russian CTSLC Spain CTDSC Low Cost CTMBO Equal to ASK CTABO High Accuracy CTMSQ Asian Hottest CTCK Small Fixed Type CTTP Square Split Core CTFlexible Rogowski coil CTDBP Square Split Core CTSCT Clamp Split Core CTUK Ring Splict Core CTOutdoor WaterProof SplitRCT Plastic Ring CTMR Tape Wrapping CTRS Plastic Ring Type CTTAS Three Phase CTD364 Low Cost 3P CTD 3Phase MCCB CTPSDH Plastic ProtectionPR 5P20 Protection CTFOX Current TransformerASK Current TransformerASR Current TransformerKBU Current Transformer0.5-0.66KV Outdoor Resin12KV Indoor Resin CT24KV Indoor Resin CT36KV Medium CT&VTMINI current transformerZero leakage protect CTResidual fire monitor CTWorldwide CT ShowroomEuropean BrandAmerican CTAsian CTGermany CTLovato CTRayleigh CTABB CTTE CTMBS CTIME CTHobut CTEFEN CTLumel CTCurrent TransducersMeter SeiresPower SeriesStandard Single ConverterVoltage SeriesPanel MetersAnalogue Panel MeterMoving Iron AC&Volt MeterMoving Iron Switch ACMoving Coil DC MeterMoving Coil Rectifier MeterSingle Phase Power MeterFrequency MeterThree Phase Power MeterPower Factor MeterDemand AmmeterLED Synchroscope MeterHour MeterDigital Panel MeterDigital AC&Volt MeterDigital DC&Volt MeterDigital Power MeterDigital Power Factor MeterDigital Frequency MeterDigital Three-Phase MeterDC ShuntsEurope DIN43703 ShuntAmerica Based ShuntSwithchBoard ShuntKWH Meter ShuntSpecial Customized ShuntRelaysTime RelayVoltage RelayCurrent RelaySolid Stage RelayLevel Control RelayLatching RelayIntermediate RelayThemal RelayArc Fault ProtectionElectronic TestersLED electronic testerSolar EnergySolar DC SurgeOther ProductsElectric Pin BusbarBusbar InsulatorWelding TorchShielded ConnectorBell transformer Quality and Certificates Downloads Distributors About Us Contact
ASK Current Transformer

ASK Current Transformer

ASK Current Transformer

Made by Qianwei Current Transformer Co., Ltd. in Liushi, Wenzhou. Tell us the ratio, accuracy class and burden and we will confirm the exact frame, the price and the lead time.

Manufacturer
Qianwei, Wenzhou China
Certification
ISO 9001 and CE

Technical data

For full specification Click Here

ASK101.4 Features  FOOT MOUNTED OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 130mm  MAX CONDUCTOR SIZE 70mm DIA  MAX BUS-BAR SIZE 100 x 10mm OR 2 x 80 x 10mm  PRIMARY RANGES FROM 500AMPS TO 2500AMPS  1AMP OR 5AMP SECONDARIES


For full specification Click Here

ASK103.3 Features  FOOT MOUNTED OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 172mm  MAX CONDUCTOR SIZE 85mm DIA  MAX BUS-BAR SIZE 2 x 100 x 10mm OR 3 x 80 x 10mm  PRIMARY RANGES FROM 800AMPS TO 3000AMPS  1AMP OR 5AMP SECONDARIES

ASK103.3
For full specification Click Here

ASK103.41 Features  FOOT MOUNTED OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 199mm  MAX BUS-BAR SIZE 103 x 41mm  PRIMARY RANGES FROM 400AMPS TO 2000AMPS  1AMP OR 5AMP SECONDARIES

ASK103.41
For full specification Click Here

ASK105.6 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 129mm  MAX BUS-BAR SIZE 100 x 55mm  PRIMARY RANGES FROM 600AMPS TO 2000AMPS  1AMP OR 5AMP SECONDARIES

ASK105.6
For full specification Click Here

ASK105.6N Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 129mm  MAX BUS-BAR SIZE 100 x 55mm  PRIMARY RANGES FROM 2500AMPS TO 5000AMPS  1AMP OR 5AMP SECONDARIES

ASK105.6N
For full specification Click Here

ASK123.3 Features  FOOT MOUNTED OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 172mm  MAX CONDUCTOR SIZE 100mm DIA  MAX BUS-BAR SIZE 123 x 30mm OR 3 x 100 x 10mm  PRIMARY RANGES FROM 1000AMPS TO 4000AMPS  1AMP OR 5AMP SECONDARIES

ASK123.3
For full specification Click Here

ASK127.4 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 159mm  MAX BUS-BAR SIZE 120 x 70mm  PRIMARY RANGES FROM 1000AMPS TO 2500AMPS  1AMP OR 5AMP SECONDARIES

ASK127.4
For full specification Click Here

ASK128.4 Features  FOOT MOUNTED OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 100mm  MAX BUS-BAR SIZE 128 x 38mm  PRIMARY RANGES FROM 400AMPS TO 4000AMPS  1AMP OR 5AMP SECONDARIES

ASK128.4
For full specification Click Here

ASK129.10 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 250mm  MAX BUS-BAR SIZE 120 x 90mm  PRIMARY RANGES FROM 1000AMPS TO 7500AMPS  1AMP OR 5AMP SECONDARIES

ASK129.10
For full specification Click Here

ASK130.5 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 180mm  MAX BUS-BAR SIZE 130 x 30mm  PRIMARY RANGES FROM 300AMPS TO 3200AMPS  1AMP OR 5AMP SECONDARIES

ASK130.5
For full specification Click Here

ASK231.5 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 49.5mm  MAX CONDUCTOR SIZE 28mm DIA.  MAX BUS-BAR SIZE 30 x 10mm  PRIMARY RANGES FROM 50AMPS TO 600AMPS  1AMP OR 5AMP SECONDARIES

ASK231.5
For full specification Click Here

ASK31.3 Features  DIN RAIL, BUS-BAR OR FOOT MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 60mm  MAX CONDUCTOR SIZE 26mm DIA  MAX BUS-BAR SIZE 30 x 10mm  PRIMARY RANGES FROM 50AMPS TO 750AMPS  1AMP OR 5AMP SECONDARIES

ASK31.3
For full specification Click Here

ASK31.5 Features  DIN RAIL, BUS-BAR OR FOOT MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 60mm  MAX CONDUCTOR SIZE 28mm DIA.  MAX BUS-BAR SIZE 2 X 20 X 10mm OR 30 X 10mm  PRIMARY RANGES FROM 40AMPS TO 600AMPS  1AMP OR 5AMP SECONDARIES

ASK31.5
For full specification Click Here

ASK318.3 Features  DIN RAIL, BUS-BAR OR FOOT MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 60mm  MAX CONDUCTOR SIZE 26mm DIA  MAX BUS-BAR SIZE 31 x 18mm  PRIMARY RANGES FROM 60AMPS TO 750AMPS  1AMP OR 5AMP SECONDARIES

ASK318.3
For full specification Click Here

ASK41.3 Features  DIN RAIL, BUS-BAR OR FOOT MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 60mm  MAX CONDUCTOR SIZE 26mm DIA  MAX BUS-BAR SIZE 40 x 12mm OR 32 x 18mm  PRIMARY RANGES FROM 100AMPS TO 800AMPS  1AMP OR 5AMP SECONDARIES

ASK41.3
For full specification Click Here

ASK41.4 Features  DIN RAIL, BUS-BAR OR FOOT MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 70mm  MAX CONDUCTOR SIZE 32mm DIA  MAX BUS-BAR SIZE 40 x 10mm OR 2 x 30 x 5mm  PRIMARY RANGES FROM 50AMPS TO 1000AMPS  1AMP OR 5AMP SECONDARIES

ASK41.4
For full specification Click Here

ASK412.4 Features  DIN RAIL, BUS-BAR OR FOOT MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 70mm  MAX CONDUCTOR SIZE 30.5mm DIA  MAX BUS-BAR SIZE 40 x 12mm OR 30 x 15mm  PRIMARY RANGES FROM 50AMPS TO 800AMPS  1AMP OR 5AMP SECONDARIES

ASK412.4
For full specification Click Here

ASK51.4 Features  FOOT MOUNTED OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 85mm  MAX CONDUCTOR SIZE 44mm DIA  MAX BUS-BAR SIZE 2 X 40 X 10 mm OR 50 X 12mm  PRIMARY RANGES FROM 100AMPS TO 1200AMPS  1AMP OR 5AMP SECONDARIES

ASK51.4
For full specification Click Here

ASK541.4 Features  FOOT MOUNTED OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 85mm  MAX CONDUCTOR SIZE 32mm DIA  MAX BUS-BAR SIZE 2 x 30x 5mm OR 40 x 10mm  PRIMARY RANGES FROM 30AMPS TO 1000AMPS  1AMP OR 5AMP SECONDARIES

ASK541.4
For full specification Click Here

ASK561.4 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 85mm  MAX CONDUCTOR SIZE 44mm DIA  MAX BUS-BAR SIZE 60 x 10mm OR 2 x 50 x 10mm  PRIMARY RANGES FROM 200AMPS TO 1200AMPS  1AMP OR 5AMP SECONDARIES

ASK561.4
For full specification Click Here

ASK61.4 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 95mm  MAX CONDUCTOR SIZE 44mm DIA  MAX BUS-BAR SIZE 63 x 10mm OR 2 x 50 x 10mm  PRIMARY RANGES FROM 200AMPS TO 1600AMPS  1AMP OR 5AMP SECONDARIES

ASK61.4
For full specification Click Here

ASK63.4 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 95mm  MAX CONDUCTOR SIZE 44mm DIA  MAX BUS-BAR SIZE 60 x 30mm OR 50 x 40mm  PRIMARY RANGES FROM 300AMPS TO 2000AMPS  1AMP OR 5AMP SECONDARIES

ASK63.4
For full specification Click Here

ASK63.6 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 88mm  MAX CONDUCTOR SIZE 30mm DIA  MAX BUS-BAR SIZE 60 x 30mm  PRIMARY RANGES FROM 200AMPS TO 2000AMPS  1AMP OR 5AMP SECONDARIES

ASK63.6
For full specification Click Here

ASK81.4 Features  FOOT OR BUS-BAR MOUNTED  SNAP FIT SECONDARY TERMINAL COVERS  INSULATED ENDS TO BUS-BAR PINCH SCREWS  TRANSFORMER WIDTH 120mm  MAX CONDUCTOR SIZE 55mm DIA  MAX BUS-BAR SIZE 80 x 10mm OR 60 x 30 OR 2 x 60 x 10mm  PRIMARY RANGES FROM 400AMPS TO 2000AMPS  1AMP OR 5AMP SECONDARIES

ASK81.4
For full specification Click Here

click to other model catalogue:

Questions about this model

How do I get a price for the ASK Current Transformer

Email [email protected] or message us on WhatsApp with the model, the ratio, the accuracy class, the burden in VA and the quantity.

What is the burden and why do you ask for it

The burden is the total termination impedance seen by the transformer: the measuring instrument, the connecting leads and the winding itself. Accuracy class cannot be guaranteed without it, and long lead runs add resistance that has to be counted.

Can this model be customised

Ratios, secondary current and mounting can often be adapted within the same frame. Send us the requirement and we will confirm what the frame allows.

Ask about the ASK Current Transformer

Give us the ratio, the accuracy class and the burden and you will get a firm model number and price.

WhatsApp