Skip to content

Kongter Test & Measurement Co., Limited  |  ISO 9001:2015 · Shenzhen, China

+86-755-2691 6832 [email protected] WhatsApp +86 135 1009 2292

Home All Products Battery Test and Management (13)AC Load Bank (5)Ground Fault Location (4)Smart Sensors (9)Meter Test and Calibration (9)Power Quality and Meter Analyzer (2)Insulation Online Monitor (1) Solutions Industries Knowledge Centre Support About Us Contact
Power Quality and Meter Analyzer

PQA-3561 Power Quality Analyzer

Features Technical Parameter Technical Specification Features Portable design and colorful touch screen Applied to standard of EN 50160 Could test 3-phase volt, null line volt, 3-phase current, null line current, etc. Up to 50 times harmonic testing with.

Model
PQA-3561
Manufacturer
Kongter Test & Measurement Co., Limited, Shenzhen, China
Quality standard
ISO 9001:2015
Customisation
Tailored configurations available on request

Send your application details straight to us on WhatsApp, WeChat or by email. We do not use enquiry forms.

Specification

Full Details for PQA-3561

Features Technical Parameter Technical Specification Features
  • Portable design and colorful touch screen
  • Applied to standard of EN 50160
  • Could test 3-phase volt, null line volt, 3-phase current, null line current, etc.
  • Up to 50 times harmonic testing with frequency spectrum graph
  • Power testing: 3-phase apparent power, active power, reactive power, power factor, and 3-phase electric power.
  • 3-phase unbalance testing with vivid chart
  • Record at least 40 times of surge current
  • Testing for wave motion, short-time flicker and long-time flicker
  • Record up to 40 times of sag and swell
  • Could have long-time record for basic (stable) power quality parameter. Recording time interval adjustable between 1 second and 30 minutes.
  • Digital oscilloscope, checking waveform for voltage and current signal
  • With Kongter Data View software for convenient analyzing of testing result
Technical Parameter

Specifications

Range

Accuracy

Voltage, Current & Frequency

Voltage: 10~700V (true rms)
Current: 0.5~3000A (true rms, with relevant CT)  
Neutral current: 0.5~25A (true rms)
Current peak: 0-3000A
Voltage peak: 0-1000V
Crest factor: 0-10
Frequency: 30~1000Hz

Voltage: ±0.2%
Current: ±0.5%
Frequency: ±0.01Hz

NOTE: Take L1 frequency as total measurement frequency.

Harmonics

Voltage: Total harmonic +1~50th
Current: Total harmonic +1~50th
K-factor: 0-10

Voltage: ±0.2(%f)
Current: ±0.2(%f)
±0.5%

Harmonic Power

Total harmonic: +1~30th
Total active harmonic power: ∑P
Total reactive harmonic power: ∑Q
Total positive active harmonic power: +∑P
Total negative active harmonic power: -∑P
Total positive reactive harmonic power: +∑Q
Total negative reactive harmonic power: -∑Q

±0.5%

Inter-harmonics

Voltage: total inter-harmonic +1~20th
Current: total inter-harmonic +1~20th

Voltage: ±0.2(%r)
Current: ±0.2(%r)

Power & Energy

Active power: 0.05~700KW
Apparent power: 0.05~700KVA
Reactive power: 0.05~700KVAR
Power factor: 0.00~1.00
Active energy: 0.01~10000kWh
Apparent energy: 0.01~10000kVAh
Reactive energy: 0.01~10000kVARh
Average power factor: 0.00~1.00

Active power: ±0.5%
Apparent power: ±0.5%
Reactive power:±1%
Power factor: ±0.005
Active energy: ±0.5%
Apparent energy: ±0.5%
Reactive energy: ±1%
Average power factor: ±0.005

Unbalance

Fundamental voltage: 10~700V (true rms)
Fundamental current: 0.5~1000A (True rms)
Fundamental frequency: 40~70Hz
Phase angle: 0~360o
Unbalance: 0.0%~100%

Voltage: ±0.5%
Current: ±0.5%
Frequency: ±0.01Hz
Phase angle: ±0.3 o
Voltage unbalance: ±0.2%
NOTE: Take L1 frequency as total measurement frequency.

Data Recording

Data logging for: 3 phase voltage, current, null current, voltage harmonic (THD and 1~25 harmonics), current harmonics (THD and 1~25 harmonics), unbalance, KW, KVA, KVAR, PF, flicker and fluctuation 

Time interval: 1s~30min adjustable
Time duration:<960 hours

Sags(Dips)/Swells

Voltage sag, voltage swells and instant interruption
Event characteristics listed: Start time, ending time, duration time(≥20ms) and voltage magnitude(rms1/2) 

Maximal event recorded: 40 times
Time:±10ms

Fluctuation

Voltage fluctuation:0.1%~10.0%

≤±5%

Flicker

 1min flicker, short-time(10min) and long-time(2h) flicker

1 minute short-time: ≤±5.5%
10 minutes short time: ≤±5%
2 hours long-time: ≤±5% 

Inrush

Inrush Current, Inrush duration, Arms ½, Expected Time, Max. Amp, Min. Amp, Threshold Amp

±10ms

Transient

Voltage transient based on 120% above of nominal voltage

Capture rate: 98.7%
Minimal detect duration: 20μs

Power wave

Measure active power, reactive power, and apparent power semi-wave and power tendency of 1 min, 3 min and 5 min. 

Semi-wave power reading±0.5%

Scope

3-phase voltage, 4-wire current, null voltage and null current waveform

Max sampling frequency: 200KHz 
Min sampling frequency: 100Hz

Technical Specification
  • LCD: 5.7” 640 x 480 TFT touch screen
  • Input Impedance: >2MΩ,20pF
  • Measurement Range: Vrms 10~1000V
  • Current: 5A, 10A, 100A, 1000A, 1500A and 3000A
      (with customized current clamps)
  • Frequency: 30Hz~1000Hz
  • Harmonic Measurement: 1~50th
  • Inrush Current: 2000A
  • Peak Voltage: 1000V
  • Internal Memory: 16MB
  • External Memory:4GB
  • Communication Port: USB
  • W.(main unit): 1.2 kg
  • Battery: 14.4V 2000mAh
    Durable for 5 hours after full charge
Request A Quote

Customers also viewed:

K-3838- ground fault locatorK-3838 Ground Fault Locator

Effective for DC fault location

BT-301 Battery Condition Analyzer for fast and accurate test of battery internal resistance/conductanceBT-301 Battery Condition Analyzer

Accurate and consistent test for battery

MTS-50 Meter Test System

Accuracy class of 0.05 & 0.1

FAQ

Questions About This Model

Is this model certified

All Kongter products are strictly accredited by the international quality standard ISO 9001:2015.

Can this be customised for my application

Yes. Customised configurations are part of the standard offering. Tell us the system voltage, capacity or load you need to cover.

What is the lead time

Lead time depends on the configuration. Message us on WhatsApp at +86 135 1009 2292 or email [email protected] with your requirement and we will confirm it.

Do you provide training and support

Yes. Kongter's R&D team develops equipment aimed at field use, and product support is part of the offering. See the support pages for what is covered.

How do I get a quotation

Message us on WhatsApp or WeChat at +86 135 1009 2292, email [email protected], or call +86-755-2691 6832.

Related Models

More From Power Quality and Meter Analyzer

View All 2

Request a Quote

Ask for a Price on PQA-3561

Tell us the system you need to test and the quantity. We reply with a quotation and lead time.