K-3986 Charger/Discharger Complex

Features Specification FAQ Order Info Features Suitable for all standby batteries and power batteries: 1.2V, 2V, 6V and 12V Multi-function in one unit: it uses 3-phase charging, constant current discharging and battery string activation Multi-condition for.

Manufacturer
Kongter Test & Measurement Co., Limited, Shenzhen, China
Quality standard
ISO 9001:2015
Customisation
Tailored configurations available on request

Send your application details straight to us on WhatsApp, WeChat or by email. We do not use enquiry forms.

Specification

Full Details for K-3986 Charger/Discharger Complex

Features Specification FAQ Order Info Features
  • Suitable for all standby batteries and power batteries: 1.2V, 2V, 6V and 12V
  • Multi-function in one unit: it uses 3-phase charging, constant current discharging and battery string activation
  • Multi-condition for operation auto-stop: time out, maximum capacity, minimum voltage threshold (for battery or string)
  • Lag-out batteries could be automatically sorted, and activation function is used to enhance their performance
  • Optional wireless DAC enables real-time PC monitor for measurement
  • State-of-the-art technique of soft-off for battery charging
  • Graphical display, showing test result with curves
  • Over voltage protection and under voltage warning function
  • Thermal protection, auto stop in overheating and auto start in normal temperature
  • Powerful data view software for complex data analyzing and report printing
  • Various models applicable to different area of industry like telecom and power utility
Specification
ParameterTesting RangeResolution & Accuracy
Total discharge voltage10~264V (Nom: 220V)
10~132V (Nom: 110V)
10~55.2V (Nom: 48V)
Resolution: 0.1V
Accuracy: 0.5%
Total charge voltage output176~288V (Nom: 220V)
90~143V (Nom: 110V)
40~57.6V (Nom: 48V)
Resolution: 0.1V
Accuracy: 0.5%
Charge/discharge cell voltage0.000V~16.00VResolution: 0.1V
Accuracy: 0.5%
Operating Time0~99h 59m—-

Mains: 100-240VAC, 50/60Hz or AC 380V, 3 phase                   
Temperature: 0℃~40℃ (Operating)          
Humidity: 5%~90% Relative Humidity
Display: 128*64 pixel LCD screen
Standard: CE market, EMC standard, LVD 60335

FAQ

Q: What models should I choose if we are to activate single Cell?
A: Kongter offers two models, BCD-3932T and BCD-3933T, for charge, discharge and activation of single cell. BCD-3932T is for measurement of 1.2V, 2V, 4V, 6V, 8V and 12V with max charge and discharge current of 100A, while BCD-3933T is for measurement of 6V and 12V ONLY with max current of 50A.

Q: What models should I choose if we want to activate battery String?
A: K-3986 series customized units are used to charge, discharge and activate battery String in single device. For example, if you want to test 48V with discharge current of 200A and charge current of 100A, you will need a customized model of 48V 200A (discharge)/48V 100A (charge).

Q: What is the principle of battery activation?
A: The charge and discharge functions in BCD-3932T. BCD-3933T and K-3986 could be used individually or comprehensively. When used comprehensively, lag-out battery will experience low-volt constant current charging and discharging in one or multi-circles (1~99). By activating the disabled Active-Material on battery electrode plate, it amends the battery malfunction caused by chemical failure and thus boosts the capacity of batteries.

Q: Can I monitor voltage of each cell during charge or discharge?
A: With optional DAC (Data Acquisition Case), you could view complete data including voltage value of each cell in PC software and K-3986 during measurement.

Q: If I do not have DAC, can I still use the PC software to monitor other data during measurement?
A: Yes, you could.

Order Info
CodeDescriptionDimension & Weight
(main unit)
DCC-22001

For battery 220 VDC
Discharge current: 0-50A
Charge current: 0-30A

L550*W440*H565mm
32kg

DCC-11001

For battery 110 VDC
Discharge current: 0-100A
Charge current: 0-40A

L550*W250*H450mm
32kg

DCC-4801

For battery 48 VDC
Discharge current: 0-150A
Charge current: 0-50A

L401*W177*H368mm
19kg

DCC-4802

For battery 48 VDC
Discharge current: 0-200A
Charge current: 0-100A

L550*W250*H450mm
21kg

Request A Quote

Customers also viewed:

Kongter test & measurement equipmentBCD-3932T Battery Activator

Single cell charger/discharger/activator

Kongter customized battery load bank with wireless monitorK-3980 Battery Load Bank

Customized for all battery systems

BT-301 Battery Condition Analyzer for fast and accurate test of battery internal resistance/conductanceBT-301 Battery Condition Analyzer

Quick test of resistance/conductance

FAQ

Questions About This Model

Is this model certified

All Kongter products are strictly accredited by the international quality standard ISO 9001:2015.

Can this be customised for my application

Yes. Customised configurations are part of the standard offering. Tell us the system voltage, capacity or load you need to cover.

What is the lead time

Lead time depends on the configuration. Message us on WhatsApp at +86 135 1009 2292 or email [email protected] with your requirement and we will confirm it.

Do you provide training and support

Yes. Kongter's R&D team develops equipment aimed at field use, and product support is part of the offering. See the support pages for what is covered.

How do I get a quotation

Message us on WhatsApp or WeChat at +86 135 1009 2292, email [email protected], or call +86-755-2691 6832.

Request a Quote

Ask for a Price on K-3986 Charger/Discharger Complex

Tell us the system you need to test and the quantity. We reply with a quotation and lead time.