Ground Fault Location

K-3837 Ground Fault Locator

Features Functions Technical Specification FAQ Features Safe to use Grould faut locator to quickly pinpoint the fault without injecting signal to DC system. No interruption to DC system itself during signal fault location with its built-in model for current.

Manufacturer
Kongter Test & Measurement Co., Limited, Shenzhen, China
Quality standard
ISO 9001:2015
Customisation
Tailored configurations available on request

Send your application details straight to us on WhatsApp, WeChat or by email. We do not use enquiry forms.

Specification

Full Details for K-3837 Ground Fault Locator

Features Functions Technical Specification FAQ Features
  1. Safe to use
    Grould faut locator to quickly pinpoint the fault without injecting signal to DC system. No interruption to DC system itself during signal fault location with its built-in model for current and voltage limitation. 
  2. High reliable designing
    It adopts main system of 16-bit micro-processor. Hardware designing strictly follows EMC standard to ensure reliability of itself and its tested systems. 
  3. Precise measurement
    It adopts high accurate current clamp for signal tracing and precise ADC for voltage sampling. This ensures the accurate measurement of voltage and resistance.
  4. User-friendly interface
    It has LCD display with vivid information indicating grounding status, waveform, insulation leveling, insulation resistance, leakage current, and direction of ground fault and so on. This user-friendly interface makes it easy and effective to use in the field. 
  5. Intelligent measurement function
    • Signal analyzer can automatically identify system voltage leveling.
    • When insulation resistance has any change, signal analyzer could quickly indicate the change.
    • Distance will not affect the ground fault detection once the signal analyzer and detector are synchronized.
    • During ground fault location, current clamp could either clamp on single cable or multiple cables for faster and more effective signal tracing.
    • Signal detector will indicate the direction of ground fault on screen once it detects any insulation problem.
    • Signal detector and analyzer have wireless communication. Complete measurement could handle different types of insulation problem in DC system.
Functions
  • Measures voltage between DC system and ground ranging from 0 to 300V.
  • Measures grounding resistance up to 999KΩ for both busbars and each branch circuit
  • It detects and measures AC voltage which interrupts in DC system. Detection range is from 0 to 288V.
  • Fast signal positioning for the point with ground fault in branch circuit.
  • It performs the function as accurate current meter with resolution up to 0.01mA.
  • It could quickly pinpoint the ground fault without injecting signal to DC system.
  • Arrow indication effectively helps users trace the signal and pinpoint the ground fault.
  • Display of insulation levelling after signal detection on each tested circuit branch.
  • Waveform display for tested circuit, indicating insulation status and current changes in tested circuit, it help users fast and effectively locate the point with grounding fault.
Technical Specification

Operation environment

  • Temperature: -30℃~+50℃
  • Humility: ≤95%

Wireless communication

  • Signal power: ≤ 10dbm
  • Signal frequency: 433Mhz
  • Sensitivity: -106dBm

Signal analyzer specification

  • For DC system of 48V, 110V, 220V or customized voltage level.
  • Voltage range of system to ground: 0-300V
  • Measurement of DC voltage to ground: 0-300V
  • Measurement of AC voltage to ground: 0-300V
  • AC interruption warning: ≥5V
  • Voltage resolution: 0.1V
  • Measurement range of system to ground: 0-999.9KΩ
  • Grounding resistance resolution: 0.1KΩ
  • Display: LCD
  • Current detection signal: 0-2mA adjustable
  • Voltage detection signal: 0-50V adjustable
  • Signal frequency: 0.16Hz and optionally no-signal mode
  • Anti-interference from DC distributed capacitance: 1000uF
  • Power supply: powered by tested circuit
  • Weight and dimension: 0.503kg, 200*117*55mm

Signal detector specification

  • Insulation resistance (in signal mode)
  • In 220V system: 0 -600KΩ
  • In 110V system: 0 -300KΩ
  • In 48V system: 0 -60KΩ
  • Resistance resolution: 0.1KΩ
  • Insulation resistance (in no-signal mode)
    In 220V system: 0 -50KΩ
    In 110V system: 0 -25KΩ
    In 48V system: 0 -10KΩ
    Resistance resolution: 0.1KΩ
  • Waveform display time: 12 seconds
  • Current measurement range: ±100mA
  • Current resolution: 0.01mA
  • Display: LCD
  • Direction indication: forward or reverse direction indicating in arrow
  • Anti-interference from DC distributed capacitance: 1000uF
  • Distance from analyzer during signal tracing: no limitation
  • Clamp jaw size: Ф30mm
  • Power supply: 5V by 4 pieces of AA standard battery
  • Weight and dimension: 0.332kg, 200*100*33mm
FAQ

Q: What may happen if I don’t trace the signal fault in DC system?
A: Multiple grounds can occur on the dc system at the same time. This situation becomes critical when the combined ground resistance becomes so low that high-voltage circuit breaker control schemes are unable to open or close breakers when required or dc system circuit breakers and or fuses open due to over current resulting in de-energization of vital operating equipment.
There are some other bad consequences due to ground fault. Please click HERE for more consequences and solutions.

Q: What are the causes of DC ground fault?
A: Some common sources of low resistances to ground include:

  • Moisture in conduit
  • Junction boxes or switch/sensor terminations
  • Wire splices soaking in water
  • Degraded cable or wire insulation caused by aging
  • Environmental conditions
  • Wild habitat and constant abrasion from vibration
  • Sharp objects piercing cable and wire insulation
  • Wires that have pulled out of their terminations and touch ground or water
  • Failed capacitors or semiconductor surge suppressors.

Q: What are the principles of tracing the signal fault?
A: There are 3 methods for signal tracing in circuit which is with earth fault:
1). Traditional Method: Sectionalization 
Traditional ways of fault location in DC system involves sectionalization or interruption of DC branches to isolate the ground fault.
2). Current Injection
This method will inject a low-frequency AC signal and use this AC signal to locate the ground fault in the DC system.
3). Use Measurement Bridge
For online fault location, ground fault locator adopts the measurement bridge (switchable resistor) inside the signal analyzer to analyze voltage, current and grounding resistance. Then it uses signal detector to pinpoint the fault.

Q: What are the advantages of using switchable bridge (resistor) measurement?
A: It does not need injection of current signal to tested system and thus no relay tripping. It is more effective for fault location and safe to the tested circuits.

Q: How do you bypass the interference during live (online) signal tracing?
A: There is always interference caused by distributed capacitance in live (online) measurement. To bypass this interference and trace the fault faster, in firmware we use very low measurement frequency; in hardware, we use high sensitive current sensor for signal tracing.

Q: How do you avoid relay tripping during signal tracing?
A: We are using very low measurement current (lower than 5mA). This will not cause relay tripping in live signal tracing.

Request A Quote

Customers also viewed:

K-3838- ground fault locatorK-3838 Ground Fault Locator

Advanced model for quick detection

BT-301 Battery Condition Analyzer for fast and accurate test of battery internal resistance/conductanceBT-301 Battery Condition Analyzer

Quick test of battery internal resistance

Kongter customized battery load bank with wireless monitorK-3980 Battery Load Bank

With real time monitor during discharge

FAQ

Questions About This Model

Is this model certified

All Kongter products are strictly accredited by the international quality standard ISO 9001:2015.

Can this be customised for my application

Yes. Customised configurations are part of the standard offering. Tell us the system voltage, capacity or load you need to cover.

What is the lead time

Lead time depends on the configuration. Message us on WhatsApp at +86 135 1009 2292 or email [email protected] with your requirement and we will confirm it.

Do you provide training and support

Yes. Kongter's R&D team develops equipment aimed at field use, and product support is part of the offering. See the support pages for what is covered.

How do I get a quotation

Message us on WhatsApp or WeChat at +86 135 1009 2292, email [email protected], or call +86-755-2691 6832.

Request a Quote

Ask for a Price on K-3837 Ground Fault Locator

Tell us the system you need to test and the quantity. We reply with a quotation and lead time.