K-1000 AC Load Bank (Resistive & Inductive)
Specification Advantages Application Protection & Control Specification Below is specification for some common models, we build more than these. Please contact Kongter to specify your customized model if you could not find the same model below. Kongter.
- Product line
- AC Load Bank
- Manufacturer
- Kongter Test & Measurement Co., Limited, Shenzhen, China
- Quality standard
- ISO 9001:2015
- Customisation
- Tailored configurations available on request
Send your application details straight to us on WhatsApp, WeChat or by email. We do not use enquiry forms.
Specification
Full Details for K-1000 AC Load Bank (Resistive & Inductive)
Below is specification for some common models, we build more than these. Please contact Kongter to specify your customized model if you could not find the same model below.
| Kongter resistive & inductive load banks-RL | ||||||
| Models | RL-6kW-AC230V | RL-30kW-AC480V | RL-60kW-AC480V | RL-100kW-AC480V | RL-200kW-AC480V | RL-500kW-AC480V |
| Capacity: | Resistive load: | Resistive load: | Resistive load: | Resistive load: | Resistive load: | Resistive load: |
| 6kW | 30kW | 60kW | 100kW | 200kW | 500kW | |
| Inductive load: | Inductive load: | Inductive load: | Inductive load: | Inductive load: | Inductive load: | |
| 4.5kVAR | 22.5kVAR | 45kVAR | 75kVAR | 150kVAR | 375kVA | |
| Customized solutions available upon request. | ||||||
| Rated Voltage: | Single Phase, | Three Phase AC480V, | ||||
| AC230V | or customer tailored | |||||
| Customized solutions available upon request. | ||||||
| Rated Current: | Resistive amperes per phase: 26A | Resistive amperes per phase: 36A | Resistive amperes per phase: 72A | Resistive amperes per phase: 120A | Resistive amperes per phase: 240A | Resistive amperes per phase: 601A |
| at 480VAC: | Reactive amperes per phase: 20A | Reactive amperes per phase: 27A | Reactive amperes per phase: 54A | Reactive amperes per phase: 90A | Reactive amperes per phase: 180A | Reactive amperes per phase: 451A |
| PF: | PF=0.8 | |||||
| Minimum Load Step: | 100W, 100VAR | 100W, 100VAR | 100W, 100VAR | 1kW, 1kVAR | 1kW, 1kVAR | 1kW, 1kVAR |
| Customized solutions available upon request. | ||||||
| Display: | Voltage, Current, Frequency, Power and PF displayed by digital meter | |||||
| Protection: | Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button. | |||||
| All protections can be configured optionally | ||||||
| Control Mode: | Manual control by MCBs or push buttons | |||||
| Air Flow: | Horizontal, Force-air cooling | |||||
| Dimension: | 51*50*110(cm) | 90*90*160(cm) | 90*90*200(cm) | 120*120*200(cm) | 90*90*200(cm) | 120*120*200(cm) |
| Options: | Handle panel or PC remote control selectable | |||||
- Compact AC load bank unit with user friendly control panel.
- Effectively applied for full load test of generator set, UPS and other AC power systems.
- Sectionalized control of input power enables any customized setting of load step and time.
- Real-time display of test current, voltage, power, power factor, time and frequency.
- Alternative control modes by local control of circuit breaker/push button or PC control.
- PC software com protocol is open for data integration to customer’s IT system.
- Emergency stop button for quick termination of AC load test.
- Protection upon over load, over voltage, over temperature, short circuit and so on.
- It adopts latest load element with high density power, safer and more durable.
- Axial flow fans with big blast capacity for quick ventilation with low noise.
- Many more customized models (resistive, inductive, capacitive or combined) available upon request
- Battery bank system
- Energy storage system
- Energy meter loop load test
- Datacenter rack heat simulating
- PV system Inverter anti-islanding test
- Voltage regulator, rectifier aging load test
- Genset, UPS load bank commission testing
- AC/DC power supply, power source commission acceptance test
Standard Protections:
- Emergency stop operation: one key stop loading
- Over temperature alarm/protection: alarm & remove load
- Fan interlock protection: loading available after fan activated
- Over voltage protection: alarm & remove load
Optional Protections:
- Blower thermal overload protection: alarm & remove load
- Lack of air volume protection: alarm & remove load
- Short circuit protection by fuse(over current protection)
- Phase sequence protection(for fans with 3 phase voltage)
- Air inlet & outlet temperature monitoring
- Or other functions as requested
Control Modes:
Two control modes available for Kongter’s series AC load banks via local panel and PC software.
- Local control mode by contactor or circuit breaker as requested by customer
- PC software control (optional)
Communication protocol of PC software is open to users for integration to their own system.
Customers also viewed:
Load Bank Type: RCDResistive/Capacitive combination
Load Bank Type: RLCResistive/Inductive/Capacitive combined
Load Bank Type: RPurely resistive load bank
FAQ
Questions About This Model
Is this model certified
All Kongter products are strictly accredited by the international quality standard ISO 9001:2015.
Can this be customised for my application
Yes. Customised configurations are part of the standard offering. Tell us the system voltage, capacity or load you need to cover.
What is the lead time
Lead time depends on the configuration. Message us on WhatsApp at +86 135 1009 2292 or email [email protected] with your requirement and we will confirm it.
Do you provide training and support
Yes. Kongter's R&D team develops equipment aimed at field use, and product support is part of the offering. See the support pages for what is covered.
How do I get a quotation
Message us on WhatsApp or WeChat at +86 135 1009 2292, email [email protected], or call +86-755-2691 6832.
Request a Quote
Ask for a Price on K-1000 AC Load Bank (Resistive & Inductive)
Tell us the system you need to test and the quantity. We reply with a quotation and lead time.