Skip to content

Kongter Test & Measurement Co., Limited  |  ISO 9001:2015 · Shenzhen, China

+86-755-2691 6832 [email protected] WhatsApp +86 135 1009 2292

Home All Products Battery Test and Management (13)AC Load Bank (5)Ground Fault Location (4)Smart Sensors (9)Meter Test and Calibration (9)Power Quality and Meter Analyzer (2)Insulation Online Monitor (1) Solutions Industries Knowledge Centre Support About Us Contact
AC Load Bank

K-1000 AC Load Bank (Resistive & Inductive)

Specification Advantages Application Protection & Control Specification Below is specification for some common models, we build more than these. Please contact Kongter to specify your customized model if you could not find the same model below. Kongter.

Product line
AC Load Bank
Manufacturer
Kongter Test & Measurement Co., Limited, Shenzhen, China
Quality standard
ISO 9001:2015
Customisation
Tailored configurations available on request

Send your application details straight to us on WhatsApp, WeChat or by email. We do not use enquiry forms.

Specification

Full Details for K-1000 AC Load Bank (Resistive & Inductive)

Specification Advantages Application Protection & Control Specification

Below is specification for some common models, we build more than these. Please contact Kongter to specify your customized model if you could not find the same model below.

Kongter resistive & inductive load banks-RL
ModelsRL-6kW-AC230VRL-30kW-AC480VRL-60kW-AC480VRL-100kW-AC480VRL-200kW-AC480VRL-500kW-AC480V
Capacity:Resistive load:Resistive load:Resistive load:Resistive load:Resistive load:Resistive load:
6kW30kW 60kW100kW200kW500kW 
Inductive load:Inductive load:Inductive load: Inductive load: Inductive load: Inductive load: 
4.5kVAR22.5kVAR45kVAR75kVAR150kVAR375kVA
Customized solutions available upon request.
Rated Voltage:Single Phase,Three Phase AC480V,
AC230Vor customer tailored
Customized solutions available upon request.
Rated Current:Resistive amperes per phase: 26AResistive amperes per phase: 36AResistive amperes per phase: 72AResistive amperes per phase: 120AResistive amperes per phase: 240AResistive amperes per phase: 601A
at 480VAC:Reactive amperes per phase: 20AReactive amperes per phase: 27AReactive amperes per phase: 54AReactive amperes per phase: 90AReactive amperes per phase: 180AReactive amperes per phase: 451A
PF:PF=0.8
Minimum Load Step:100W, 100VAR100W, 100VAR100W, 100VAR1kW, 1kVAR1kW, 1kVAR1kW, 1kVAR
Customized solutions available upon request.
Display:Voltage, Current, Frequency, Power and PF displayed by digital meter
Protection:Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button.
All protections can be configured optionally
Control Mode:Manual control by MCBs or push buttons
Air Flow:Horizontal, Force-air cooling
Dimension:51*50*110(cm)90*90*160(cm)90*90*200(cm)120*120*200(cm)90*90*200(cm)  120*120*200(cm)     
Options:Handle panel or PC remote control selectable 
Advantages
  • Compact AC load bank unit with user friendly control panel.
  • Effectively applied for full load test of generator set, UPS and other AC power systems.
  • Sectionalized control of input power enables any customized setting of load step and time.
  • Real-time display of test current, voltage, power, power factor, time and frequency.
  • Alternative control modes by local control of circuit breaker/push button or PC control.
  • PC software com protocol is open for data integration to customer’s IT system.
  • Emergency stop button for quick termination of AC load test.
  • Protection upon over load, over voltage, over temperature, short circuit and so on.
  • It adopts latest load element with high density power, safer and more durable.
  • Axial flow fans with big blast capacity for quick ventilation with low noise.
  • Many more customized models (resistive, inductive, capacitive or combined) available upon request
Application
  • Battery bank system
  • Energy storage system
  • Energy meter loop load test
  • Datacenter rack heat simulating
  • PV system Inverter anti-islanding test
  • Voltage regulator, rectifier aging load test
  • Genset, UPS load bank commission testing
  • AC/DC power supply, power source commission acceptance test 
Protection & Control

Standard Protections:

  • Emergency stop operation: one key stop loading
  • Over temperature alarm/protection: alarm & remove load
  • Fan interlock protection: loading available after fan activated
  • Over voltage protection: alarm & remove load

Optional Protections:

  • Blower thermal overload protection: alarm & remove load
  • Lack of air volume protection: alarm & remove load
  • Short circuit protection by fuse(over current protection)
  • Phase sequence protection(for fans with 3 phase voltage)
  • Air inlet & outlet temperature monitoring
  • Or other functions as requested

Control Modes:
Two control modes available for Kongter’s series AC load banks via local panel and PC software.

  • Local control mode by contactor or circuit breaker as requested by customer
  • PC software control (optional)
    Communication protocol of PC software is open to users for integration to their own system. 
Request A Quote

Customers also viewed:

Kongter AC load bank.www.kongter.comLoad Bank Type: RCD

Resistive/Capacitive combination

Kongter AC load bank.www.kongter.comLoad Bank Type: RLC

Resistive/Inductive/Capacitive combined

Kongter AC load bank.www.kongter.comLoad Bank Type: R

Purely resistive load bank

FAQ

Questions About This Model

Is this model certified

All Kongter products are strictly accredited by the international quality standard ISO 9001:2015.

Can this be customised for my application

Yes. Customised configurations are part of the standard offering. Tell us the system voltage, capacity or load you need to cover.

What is the lead time

Lead time depends on the configuration. Message us on WhatsApp at +86 135 1009 2292 or email [email protected] with your requirement and we will confirm it.

Do you provide training and support

Yes. Kongter's R&D team develops equipment aimed at field use, and product support is part of the offering. See the support pages for what is covered.

How do I get a quotation

Message us on WhatsApp or WeChat at +86 135 1009 2292, email [email protected], or call +86-755-2691 6832.

Request a Quote

Ask for a Price on K-1000 AC Load Bank (Resistive & Inductive)

Tell us the system you need to test and the quantity. We reply with a quotation and lead time.