Load Cells

H3

S type load cell

1、 H3 load cells are available in the capacities 25kg to 30t and 100lb to 20klb . 2、 Alloy steel,sealed by adhesive inside,oil-proof,waterproof and anti-corrosion,suitable for all

H3 S type load cell

Specification

H3 Data

  • 50.8 (2.
  • 12.7 (0.
  • 16.1 (0.
  • M8 15.7 (0.
  • 0.1~1.5t 76.2 (3.
  • 50.8 (2.
  • 19.0 (0.
  • 22.4 (0.
  • M10 ×1.5 15.3 (0.
  • 0.2~0.75t 76.2 (3.
  • 50.8 (2.
  • 19.0 (0.
  • 22.4 (0.
  • M12 ×1.75 13.6 (0.
  • 1~1.5t 76.2 (3.
  • 50.8 (2.
  • 25.4 (1.
  • 28.8 (1.
  • M12×1.75 12.1 (0.
  • 2~5t 101.6 (4.
  • 76.2 (3.
  • 25.4 (1.
  • 28.8 (1.
  • M20×1.5 20 (0.
  • 7.5~10t 175 (6.
  • 125 (4.
  • 50 (1.
  • / M33×3 40.2 (1.
  • 15~20t 200 (7.
  • 160 (6.
  • 60 (2.
  • / M42×3 51 (2.
  • 30t 230 (9.
  • 190 (7.
  • 80 (3.
  • / M42×3 57.5 (2.
  • 100~300lb 63.5 (2.
  • 50.8 (2.
  • 12.7 (0.
  • 15.9 (0.
  • 1/4—28UNF 10.1(0.
  • 500lb 63.5 (2.
  • 50.8 (2.
  • 19.05 (0.
  • 22.25 (0.
  • 1/2—20UNF 0.75~1.5klb 63.5 (2.
  • 50.8 (2.
  • 19.05 (0.
  • 22.25 (0.
  • 1/2—20UNF 2~2.5klb 63.5 (2.
  • 50.8 (2.
  • 25.4 (1.
  • 28.6 (1.
  • 1/2—20UNF 3klb 101.6 (4.
  • 76.2 (3.
  • 25.4 (1.
  • 28.6 (1.
  • 1/2—20UNF 15.24 (0.
  • 5~10klb 101.6 (4.
  • 76.2 (3.
  • 25.4 (1.
  • 28.6 (1.
  • 3/4—16UNF 15.24 (0.
  • 15klb 139.7 (5.
  • 101.6 (4.
  • 31.75 (1.
  • 34.95 (1.
  • 1—14UNS 31 (1.
  • 20klb 177.8 (7.
  • 127 (5.
  • 50.8 (2.
  • 54 (2.
  • 5/4—12UNF 39.9 (1.
  • Capacity t 0.025/0.05/0.1/0.15/0.2/0.25/0.3/0.5/0.6/0.75/1/1.5/2/2.5/3/5/7.5/10/15/20/30 lb 100/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K Accuracy C2 C3 C4 A5S A5M B10S B10M Approval OIML R60 C3 OIML R60 C4 Maximum number of verification intervals n max 2000 3000 4000 5000 5000 10000 10000 Minimum load cell verification interval v min Emax /5000 Emax /10000 Emax /14000 Emax /15000 Emax /15000 Emax /10000 Emax /10000 Combined error %FS ≤±0.030 ≤±0.020 ≤±0.018 ≤±0.018 ≤±0.026 ≤±0.035 ≤±0.050 Creep %FS /30min ≤±0.024 ≤±0.016 ≤±0.012 ≤±0.012 ≤±0.017 ≤±0.030 ≤±0.040 Temperature effect on sensitivity %FS/10℃ ≤±0.017 ≤±0.011 ≤±0.009 ≤±0.009 ≤±0.013 ≤±0.030 ≤±0.040 Temperature effect on zero %FS/10℃ ≤±0.023 ≤±0.015 ≤±0.010 ≤±0.010 ≤±0.014 ≤±0.030 ≤±0.020 Output sensitivity mv/v 2.0±0.004(Metric) 3.0±0.008(Imperial) Input resistance Ω 350±3.5 Output resistance Ω 351±2.0 Insulation resistance MΩ ≥ 5000(50VDC) Zero balance %FS 1.5(Metric) 1.0(Imperial) Temperature, compensated ℃ -10~+40 Temperature, operating ℃ -35~+65 Excitation, Recommended V 5~12(DC) Excitation, Max V 18(DC) Safe overload %FS 150 Ultimate overload %FS 300

FAQ

Questions Buyers Ask Us

What Is the Lead Time

Our delivery time is normally less than 15 days.

How Do I Get a Quotation

Email [email protected] or message our 7x24 hotline on WhatsApp at +86 153 9708 2308 with the model and the quantity, and we will reply with a quotation.

Quote H3

Send us the model and the quantity and we will reply with a price and a lead time.

WhatsApp Email