Two-Way Silicone Foley Catheter

A two-way indwelling urethral catheter manufactured from medical grade silicone for urinary bladder drainage.

Close-up of silicone Foley catheter tips with inflated and deflated balloons on black background
Close-up of silicone Foley catheter tips with inflated and deflated balloons on black background
Product Overview

What This Product Is

A two-way indwelling urethral catheter manufactured from medical grade silicone for urinary bladder drainage. Integrated with an X-ray line along the entire tube and distal tip, the device includes a guidewire to balance flexibility and rigidity during placement. Designed for indwelling duration of up to 28 days, it is supplied sterile via ethylene oxide gas across sizes 12Fr to 26Fr.

  • Type: Two-way Foley catheter
  • Material: Medical grade silicone
  • French sizes: 12Fr / 14Fr / 16Fr / 18Fr / 20Fr / 22Fr / 24Fr / 26Fr
  • Length: 400 mm
Key Benefits

Why Buyers Pick This Reference

  • Medical grade silicone construction provides a 100% latex-free fluid pathway suitable for sensitised patients
  • Integrated guidewire balances catheter flexibility and structural rigidity to aid controlled insertion through the urethra
  • Radiopaque line running along the entire shaft and distal tip enables X-ray verification under fluoroscopy
  • Colour-coded inflation valves allow ward staff to rapidly identify French sizes from 12Fr to 26Fr
  • Rated for indwelling placement up to 28 days, reducing catheter replacement frequency for catheterised patients
Gallery

The Product As It Ships

Technical Features

How It Is Built

  • Moulded from medical grade silicone with a two-way design for drainage and balloon inflation
  • Equipped with a guidewire to deliver targeted flexibility and rigidity during catheter placement
  • Continuous X-ray detective line integrated throughout the complete tube wall and distal tip
  • Standard colour-coded valve connectors covering sizes from 12Fr white through 26Fr pink
  • Supplied sterile following ethylene oxide gas treatment for up to 28 days continuous use
Specifications

Sizes Packing and Materials

Only values printed on the original product documentation are listed. Anything still marked TBC is confirmed per order rather than guessed here.

Two-Way Silicone Foley Catheter specifications
TypeTwo-way Foley catheter
MaterialMedical grade silicone
French sizes12Fr / 14Fr / 16Fr / 18Fr / 20Fr / 22Fr / 24Fr / 26Fr
Length400 mm
Balloon volume5-15 ml (12Fr-16Fr), 30 ml (16Fr-26Fr)
Colour coding12Fr White, 14Fr Green, 16Fr Orange, 18Fr Red, 20Fr Yellow, 22Fr Violet/purple, 24Fr Blue, 26Fr Pink
Insertion aidIntegrated guidewire
RadiopacityX-ray line integrated overall whole tube and distal tip
SterilisationEthylene oxide (EO Gas)
Indwelling durationMax 28 days suggested
MOQTBC
Lead timeTBC
  • Constructed entirely from medical grade silicone to maintain lumen patency and eliminate latex exposure
  • Embedded radiopaque compound forms the continuous X-ray detection line through the tube and tip
Who It Is For

Buyers This Product Was Built For

  • Medical device distributors sourcing latex-free two-way indwelling urinary drainage catheters for hospital supply
  • OEM brand owners requiring custom packaging and catalogue numbering for urology device product lines
  • Hospital purchasing organisations tendering for sterile silicone Foley catheters with integrated X-ray lines
  • Importers needing CE, FDA and ISO approved single-use urological consumables from China
Problems It Solves

What Goes Wrong Without It

  • Catheter buckling during difficult insertions is mitigated by the integrated guidewire providing necessary shaft rigidity
  • Latex protein allergies in long-term patients are avoided by utilising inert medical grade silicone
  • Uncertain tip positioning is resolved through the continuous X-ray detective line running to the tip
  • Size confusion during clinical selection is prevented by standard international colour-coded inflation valves
Application Scenarios

Where It Is Used

Urinary retention management requiring closed continuous bladder drainage for up to 28 days

Urological procedures requiring radiopaque tracking to confirm distal tip placement inside the bladder

Patients with documented natural rubber latex allergies requiring a fully inert silicone indwelling catheter

Difficult urethral catheterisation where a guidewire is required to provide insertion rigidity

Manufacturing

How It Is Made

  • Medical grade silicone is extruded and moulded into two-lumen shafts with integrated radiopaque lines
  • Guidewire is inserted and retention balloon is bonded securely to the catheter shaft
  • Colour-coded inflation ports and drainage funnels are assembled to match French size specifications
  • Catheters undergo packaging, sealing and ethylene oxide gas sterilisation under controlled conditions
Quality Control

What Is Checked Before It Ships

  • Balloon retention capacity and seal integrity are tested across rated 5-15 ml and 30 ml volumes
  • Radiopaque line continuity is inspected to verify visibility across the full shaft and distal tip
  • Sterilisation verification is completed using validated ethylene oxide processing records
  • Partner manufacturing facilities hold active CE, FDA and ISO quality system approvals
Customization

What Can Be Changed For Your Brand

  • Private-label packaging, custom sterile pouch artwork and specific distributor catalogue numbering
  • Selection of individual French sizes and balloon volumes to match regional tender requirements
  • Custom outer shipping cartons and barcoded labelling configured to your import guidelines
Comparison

How It Compares With The Alternatives

Latex Foley CatheterSilicone avoids latex sensitisation and supports 28-day indwelling, whereas latex is limited to shorter durations and risks allergic reactions
Three-Way Silicone Foley CatheterTwo-way catheters provide routine drainage at lower cost, but lack the third irrigation lumen required for continuous bladder irrigation
Standard Silicone Catheter without GuidewireCatheters with guidewires provide extra shaft support during insertion, whereas guidewire-free versions may buckle in difficult anatomies
Use Guide

How It Is Used

  • Select the required French size and balloon volume based on patient requirements and colour-coded valve
  • Inspect the sterile peel pouch for package integrity prior to opening under aseptic technique
  • Advance the catheter with guidewire through the urethra until urine flow confirms bladder entry
  • Inflate the retention balloon with sterile water according to the specified balloon capacity
  • Ensure continuous drainage into a collection bag, not exceeding the maximum 28 days suggested duration

Two-Way Silicone Foley Catheter Buyer Questions

What French sizes and balloon volumes are available?

Sizes range from 12Fr to 26Fr with a standard 400 mm length. Balloon volumes are 5-15 ml for sizes 12Fr to 16Fr, and 30 ml for sizes 16Fr to 26Fr.

How is the catheter sterilised?

Each device is sterilised using ethylene oxide (EO gas) and sealed in an individual sterile package.

What is the recommended indwelling duration in the human body?

The suggested maximum duration for continuous indwelling placement in the human body is 28 days.

Can the catheter tip be visualised under X-ray?

Yes. An X-ray detective line is integrated throughout the entire tube and distal tip for radiographic confirmation.

What regulatory certifications do your partner factories hold?

All manufacturers invested in by Nineluck hold CE, FDA and ISO approvals to support customs clearance and compliance.

Can you supply this product under OEM private labelling?

Yes. We accept customer OEM and ODM design work, including custom pouch artwork, carton specifications and catalogue numbers.

What is the minimum order quantity and lead time?

MOQ and lead time are TBC. Contact our export team with your target French sizes and balloon volumes to confirm specifications.

Quote Two-Way Silicone Foley Catheter

Send the size, the variant and the quantity. The reply carries pricing, packing and the CE, FDA and ISO certificate copies for this catalogue number.